Your browser doesn't support javascript.
loading
Risk Factors of Extubation Failure in Intubated Preterm Infants at a Tertiary Care Hospital in Oman.
Mandhari, Hilal Al; Al Riyami, Buthina; Khan, Ashfaq; Nonoyama, Mika; Rizvi, Syed G A.
Afiliação
  • Mandhari HA; Department of Child Health, Sultan Qaboos University Hospital, Muscat, Oman.
  • Al Riyami B; College of Medicine and Health Sciences, Sultan Qaboos University, Muscat, Oman.
  • Khan A; Department of Child Health, Sultan Qaboos University Hospital, Muscat, Oman.
  • Nonoyama M; Department of Respiratory Therapy and Child Health Evaluative Sciences, Hospital for Sick Children, Toronto, Canada.
  • Rizvi SGA; Faculty of Health Sciences, Ontario Tech University, Oshawa, Canada.
Sultan Qaboos Univ Med J ; 22(2): 247-252, 2022 May.
Article em En | MEDLINE | ID: mdl-35673279
Objectives: This study aimed to determine extubation failure (EF) rate among intubated preterm infants (<37 weeks gestational age [GA]) admitted to a tertiary care neonatal intensive care unit (NICU) in Oman and identify the risk factors associated with EF. Methods: This retrospective study included all intubated preterm infants (<37 weeks GA) admitted to the NICU at Sultan Qaboos University Hospital (SQUH) from January 2013 to December 2017. EF was defined as reintubation within seven days of planned extubation. Demographics, ventilation parameters, blood gas values and other possible risk factors of EF were collected. Statistical analysis included comparisons between EF and extubation success (ES) groups and a binary logistic regression analysis. Results: A total of 190 preterm infants were intubated during the study period with 140 eligible for analysis. A total of 106 infants (75.7%) were successfully extubated while 34 (24.3%) failed extubation. GA <28 weeks (P = 0.029), lower 1-minute Apgar score (P = 0.023) and patent ductus arteriosus diagnosis (P = 0.018) were significantly associated with EF. After the multivariate analysis, only GA <28 weeks predicted EF with an adjusted odds ratio of 2.621 (95% confidence interval: 1.118 - 6.146). Conclusion: EF rate in preterm infants admitted at the NICU of SQUH was within international rates. GA <28 weeks was the only predictor of the identified extubation failure. Neonatal practitioners need to seriously consider extreme prematurity in the extubation process and consider implementing strategies to decrease extubation failure in this group of fragile infants.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Recém-Nascido Prematuro / Extubação Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Infant / Newborn País/Região como assunto: Asia Idioma: En Revista: Sultan Qaboos Univ Med J Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Omã País de publicação: Omã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Recém-Nascido Prematuro / Extubação Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Infant / Newborn País/Região como assunto: Asia Idioma: En Revista: Sultan Qaboos Univ Med J Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Omã País de publicação: Omã