Within-patient evaluation of chewing efficiency and maximum bite force of conventional dentures, fixed prostheses, and milled bar overdentures used for All-on-4 implant rehabilitation of atrophied mandibular ridges: A short-term randomized trial.
ELsyad, Moustafa Abdou; Tella, Eman Abd El Sattar; Mohamed, Shahinaz Sayed; Mahrous, Ahmed Ibrahim.
Afiliação
  • ELsyad MA; Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Eldakahlia, Egypt.
  • Tella EAES; Department of Basic and Clinical Oral Sciences, College of Dentistry, Umm Al Qura University, Saudi Arabia.
  • Mohamed SS; Department of Removable Prosthodontics, Faculty of Dentistry, Beni-Suef University, Egypt.
  • Mahrous AI; Vision college Jeddah for Dentistry and Nursing, Geddah, Saudi Arabia.
Clin Implant Dent Relat Res ; 24(4): 522-531, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35679127
ABSTRACT

PURPOSE:

This crossover study aimed to evaluate chewing efficiency and maximum bite force (BF) of conventional dentures, fixed prostheses, and milled bar overdentures (MO) used for All-on-4 implant rehabilitation of atrophied mandibular ridges.

METHODS:

Sixteen edentulous participants with resorbed mandibular ridges received new conventional dentures (CD, control). Four implants were inserted after 3 months in the mandible using the All-on-4 protocol and loaded immediately with acrylic prosthesis. In a crossover manner, each patient had either fixed restoration (FR, 12 occlusal units) or MO (14 occlusal units) randomly in a crossover study design. Chewing efficiency was evaluated using the mixing ability test. The hue deviation (HD) of two-colored gum was calculated after being chewed for 5, 10, 20, 30, and 50 masticatory cycles. Maximum BF was evaluated using a BF device. HD and BF were measured after using CD, FR, and MO prostheses.

RESULTS:

For all groups, the highest HD (i.e., the lowest chewing efficiency) was noted with 5 strokes, followed by 10, 20, 30 strokes, and the lowest HD (i.e., the highest chewing efficiency) was noted with 50 strokes. For all number of chewing strokes, CD showed the highest HD, then FR, and MO recorded the lowest HD. The highest BF was observed with MO, then FR, and the lowest BF was noted with CD.

CONCLUSION:

Within the limitations of this short-term investigation, both FR and MO used for All-on-4 implant rehabilitation of patients with resorbed mandibular ridges improve masticatory efficiency and maximum BFs compared to CD. However, MO was associated with significantly higher chewing efficiency and maximum BFs than fixed prosthesis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Revestimento de Dentadura Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Egito País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Revestimento de Dentadura Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Egito País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA