Investigation of an Uncommon Artifact during Reducing Capillary Electrophoresis-Sodium Dodecyl Sulfate Analysis of a Monoclonal Antibody with Dynamic Light Scattering and Reversed Phase High-Performance Liquid Chromatography.
Gao, Han; Wang, Si-Tao; Hu, Feng; Shen, Bin-Bin; Sun, Min-Fei; Wang, Haibin; Li, Lei; Fang, Wei-Jie.
Afiliação
  • Gao H; Institute of Drug Metabolism and Pharmaceutical Analysis, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
  • Wang ST; Hangzhou Institute of Innovative Medicine, Zhejiang University, Hangzhou, 310016, China.
  • Hu F; Institute of Drug Metabolism and Pharmaceutical Analysis, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
  • Shen BB; Zhejiang Bioray Biopharmaceutical Co., Taizhou, 317000, China.
  • Sun MF; Institute of Drug Metabolism and Pharmaceutical Analysis, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
  • Wang H; Hangzhou Institute of Innovative Medicine, Zhejiang University, Hangzhou, 310016, China.
  • Li L; Institute of Drug Metabolism and Pharmaceutical Analysis, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
  • Fang WJ; Hangzhou Institute of Innovative Medicine, Zhejiang University, Hangzhou, 310016, China.
Pharm Res ; 39(8): 1959-1968, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35701679
PURPOSES: In reducing capillary electrophoresis sodium dodecyl sulfate (CE-SDS) analysis of a monoclonal antibody (mAb-1), the peak area ratio of heavy chain (HC) to light chain (LC) was out of balance, while multiple artifact peaks were observed following the migration of HC. The main purposes of this study were to describe the techniques utilized to eliminate this artifact and clarify the root cause for this interesting phenomenon. METHODS: We optimized the CE-SDS analysis of mAb-1 by a vairety of techniques including changing the concentration of protein or replacing SDS with a more hydrophobic surfactant (i.e., sodium hexadecyl sulfate (SHS) or sodium tetradecyl sulfate (STS) instead of SDS) in sample and/or the sieving gel buffer. Dynamic light scattering (DLS) and reversed phase high-performance liquid chromatography (RP-HPLC) were used to study the protein-surfactant complex. RESULTS: The artifact could be partially mitigated by reducing the protein concentration and replacing SDS with SHS or STS in the sample and/or the sieving gel buffer solutions. Due to replacing a more hydrophobic surfactant, the HC-surfactant complex formed was more resistant to dissociation, preventing additional hydrophobic HC-HC interaction and aggregation, thus eliminating the artifact problem. CONCLUSIONS: DLS and RP-HPLC are powerful supplementary techniques in characterizing the protein-surfactant complex, and hydrophobic surfactants such as SHS and STS could afford more normal electropherograms during the analysis of mAbs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Anticorpos Monoclonais Idioma: En Revista: Pharm Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos