Emulating the Effective Ankle Stiffness of Commercial Prosthetic Feet Using a Robotic Prosthetic Foot Emulator.
Halsne, Elizabeth G; Curran, Carl S; Caputo, Joshua M; Hansen, Andrew H; Hafner, Brian J; Morgenroth, David C.
Afiliação
  • Halsne EG; Center for Limb Loss and Mobility, VA Puget Sound Health Care System, 1660 South Columbian Way (MS 151), Seattle, WA 98108; Department of Rehabilitation Medicine, University of Washington, 1959 NE Pacific Street, Box 356490, Seattle, WA 98195.
  • Curran CS; Human Motion Technologies LLC d/b/a Humotech, 630 William Pitt Way U-PARC, Building A2, Pittsburgh, PA 15238.
  • Caputo JM; Human Motion Technologies LLC d/b/a Humotech, 630 William Pitt Way U-PARC, Building A2, Pittsburgh, PA 15238.
  • Hansen AH; Minneapolis Adaptive Design & Engineering (MADE) Program, Minneapolis VA Health Care System, 1 Veterans Drive (MS 151), Minneapolis, MN 55417; Departments of Rehabilitation Medicine & Biomedical Engineering, University of Minnesota, Rehabilitation Science Program, MMC 388, 420 Delaware Stree
  • Hafner BJ; Department of Rehabilitation Medicine, University of Washington, 1959 NE Pacific Street, Box 356490, Seattle, WA 98195.
  • Morgenroth DC; Center for Limb Loss and Mobility, VA Puget Sound Health Care System, 1660 South Columbian Way (MS 151), Seattle, WA 98108; Department of Rehabilitation Medicine, University of Washington, 1959 NE Pacific Street, Box 356490, Seattle, WA 98195.
J Biomech Eng ; 144(11)2022 11 01.
Article em En | MEDLINE | ID: mdl-35722979
ABSTRACT
Prosthetic foot selection for individuals with lower limb amputation relies primarily on clinician judgment. The prosthesis user rarely has an opportunity to provide experiential input into the decision by trying different feet. A prosthetic foot emulator (PFE) is a robotic prosthetic foot that could facilitate prosthesis users' ability to trial feet with different mechanical characteristics. Here, we introduce a procedure by which a robotic PFE is configured to emulate the sagittal plane effective ankle stiffness of a range of commercial prosthetic forefeet. Mechanical testing was used to collect data on five types of commercial prosthetic feet across a range of foot sizes and intended user body weights. Emulated forefoot profiles were parameterized using Bezier curve fitting on ankle torque-angle data. Mechanical testing was repeated with the PFE, across a subset of emulated foot conditions, to assess the accuracy of the emulation. Linear mixed-effects regression and Bland-Altman Limits of Agreement analyses were used to compare emulated and commercial ankle torque-angle data. Effective ankle stiffness of the emulated feet was significantly associated with the corresponding commercial prosthetic feet (p <0.001). On average, the emulated forefeet reproduced the effective ankle stiffness of corresponding commercial feet within 1%. Furthermore, differences were independent of prosthetic foot type, foot size, or user body weight. These findings suggest that commercial prosthetic foot properties can be effectively mimicked by a PFE, which is the important first step toward enabling prosthesis users to quickly trial different feet using a PFE as part of prosthetic foot prescription.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membros Artificiais / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Eng Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membros Artificiais / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Eng Ano de publicação: 2022 Tipo de documento: Article
...