Your browser doesn't support javascript.
loading
Determination of Time in Range Associated With HbA1c ≤7% in a Prospective Cohort of Patients With Type 1 Diabetes Using CGM for Three Months.
Gómez, Ana María; Henao C, Diana Cristina; Rebolledo, Martín; Jaramillo P, Pablo Esteban; Muñoz V, Oscar Mauricio; Niño G, Laura María; Yepes C, Carlos Augusto.
Afiliação
  • Gómez AM; Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Henao C DC; Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Rebolledo M; Department of Internal Medicine, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Jaramillo P PE; Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Muñoz V OM; Department of Internal Medicine, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Niño G LM; Pontificia Universidad Javeriana, Bogotá, Colombia.
  • Yepes C CA; Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia.
J Diabetes Sci Technol ; : 19322968221108424, 2022 Jul 05.
Article em En | MEDLINE | ID: mdl-35791440
ABSTRACT

INTRODUCTION:

Finding a goal of time in range (%TIR) that defines good glycemic control is necessary. Previous retrospective studies suggest good concordance between HbA1c ≤7% with a TIR >70%; however, the studies that included the largest number of patients used blood glucose measurement data with a follow-up time of less than 90 days. This study defined the TIR value that best discriminates HbA1c ≤7%.

METHODS:

We performed a prospective study of diagnostic tests based on a cohort of patients with type 1 diabetes (T1D) treated with a hybrid closed loop (HCL) followed for three months. The ability of %TIR to distinguish patients with HbA1c ≤7% was evaluated through receiver operating characteristic curve analysis. We determined the %TIR cutoff point with the best operating characteristics.

RESULTS:

A total of 118 patients were included (58.1% women, 47% overweight or obese, and 33% with high glycemic variability). A moderate negative correlation (R = -.54, P < .001) was found between %TIR and HBA1c. The discrimination ability was moderate, with an area under the curve of 0.7485 (95% confidence interval = 0.6608-0.8363). The cutoff point that best predicted HbA1c ≤7% was %TIR ≥75.5 (sensitivity 70%, specificity 67%). The findings were similar among those with a coefficient of variation (CV%) ≥36%.

CONCLUSIONS:

Our data suggest that the %TIR adequately identifies patients with HbA1c ≤7%. A target of TIR ≥75%, rather than the currently recommended TIR ≥70%, may be a more suitable value for optimal glycemic control.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Colômbia País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Colômbia País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA