Your browser doesn't support javascript.
loading
q value and parent energy optimization using a low-voltage ionization approach increases resolution in linear ion trap mass spectrometry.
Madama, Simone; Falletta, Ermelinda; Malvandi, Amir Mohammad; Arzoni, Kevin; Brogna, Carlo; Varelli, Marco; Bertelli, Matteo; Conti, Matteo; Larini, Martina; Guidugli, Federico; Traldi, Pietro; Cristoni, Simone.
Afiliação
  • Madama S; I.S.B. - Ion Source & Biotechnologies srl, Milan, Italy.
  • Falletta E; University of Milan, Milan, Italy.
  • Malvandi AM; Laboratory of Experimental Biochemistry and Molecular Biology, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
  • Arzoni K; I.S.B. - Ion Source & Biotechnologies srl, Milan, Italy.
  • Brogna C; Craniomed, Avellino, Italy.
  • Varelli M; Diagnostic Institute Varelli, Naples, Italy.
  • Bertelli M; MAGI'S LAB srl, Trento, Italy.
  • Conti M; Analytical Chemistry, Sant'Orsola Hospital, Bologna, Italy.
  • Larini M; I.S.B. - Ion Source & Biotechnologies srl, Milan, Italy.
  • Guidugli F; Thermo Fisher Corporation, Milan, Italy.
  • Traldi P; Institute of Paediatric Research Città della Speranza, Padova, Italy.
  • Cristoni S; I.S.B. - Ion Source & Biotechnologies srl, Milan, Italy.
J Mass Spectrom ; 57(8): e4876, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35941810
In this work, the isolation step in the linear ion trap was performed using different "q values" conditions at a low collision-induced dissociation (CID) energy leading to the parent ion resolution improvements, reasonably due to better ion energy distribution. According to the results, we obtained a greater resolution and mass accuracy operating in both traditional electrospray and low voltage ionization near the q value = 0.778 and with a CID energy of 10%. This effect was evaluated with low-molecular-mass compounds (skatole and arginine). The proposed optimization yielded a superior instrument performance without adding technological complexity to mass spectrometry analyses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray Idioma: En Revista: J Mass Spectrom Assunto da revista: BIOQUIMICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Reino Unido