Your browser doesn't support javascript.
loading
Evaluation of auto-segmentation for EBRT planning structures using deep learning-based workflow on cervical cancer.
Wang, Jiahao; Chen, Yuanyuan; Xie, Hongling; Luo, Lumeng; Tang, Qiu.
Afiliação
  • Wang J; Department of Radiation Oncology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310006, Zhejiang, China.
  • Chen Y; Department of Radiation Oncology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310006, Zhejiang, China.
  • Xie H; Department of Radiation Oncology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310006, Zhejiang, China.
  • Luo L; Department of Radiation Oncology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310006, Zhejiang, China.
  • Tang Q; Department of Radiation Oncology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310006, Zhejiang, China. qiutang@zju.edu.cn.
Sci Rep ; 12(1): 13650, 2022 08 11.
Article em En | MEDLINE | ID: mdl-35953516
ABSTRACT
Deep learning (DL) based approach aims to construct a full workflow solution for cervical cancer with external beam radiation therapy (EBRT) and brachytherapy (BT). The purpose of this study was to evaluate the accuracy of EBRT planning structures derived from DL based auto-segmentation compared with standard manual delineation. Auto-segmentation model based on convolutional neural networks (CNN) was developed to delineate clinical target volumes (CTVs) and organs at risk (OARs) in cervical cancer radiotherapy. A total of 300 retrospective patients from multiple cancer centers were used to train and validate the model, and 75 independent cases were selected as testing data. The accuracy of auto-segmented contours were evaluated using geometric and dosimetric metrics including dice similarity coefficient (DSC), 95% hausdorff distance (95%HD), jaccard coefficient (JC) and dose-volume index (DVI). The correlation between geometric metrics and dosimetric difference was performed by Spearman's correlation analysis. The right and left kidney, bladder, right and left femoral head showed superior geometric accuracy (DSC 0.88-0.93; 95%HD 1.03 mm-2.96 mm; JC 0.78-0.88), and the Bland-Altman test obtained dose agreement for these contours (P > 0.05) between manual and DL based methods. Wilcoxon's signed-rank test indicated significant dosimetric differences in CTV, spinal cord and pelvic bone (P < 0.001). A strong correlation between the mean dose of pelvic bone and its 95%HD (R = 0.843, P < 0.001) was found in Spearman's correlation analysis, and the remaining structures showed weak link between dosimetric difference and all of geometric metrics. Our auto-segmentation achieved a satisfied agreement for most EBRT planning structures, although the clinical acceptance of CTV was a concern. DL based auto-segmentation was an essential component in cervical cancer workflow which would generate the accurate contouring.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias do Colo do Útero / Aprendizado Profundo Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias do Colo do Útero / Aprendizado Profundo Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China