Your browser doesn't support javascript.
loading
Can Direct-Immersion Aqueous-Aqueous Microextraction Be Achieved When Using a Single-Drop System?
Wang, Lina; Zhang, Jinghui; Shen, Wei; Zeng, Xuemin; Lee, Hian Kee; Tang, Sheng.
Afiliação
  • Wang L; School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • Zhang J; School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • Shen W; School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • Zeng X; School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • Lee HK; School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • Tang S; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore.
Anal Chem ; 94(36): 12538-12545, 2022 09 13.
Article em En | MEDLINE | ID: mdl-36048431
For the analysis of biological analytes in complex matrices, it is difficult to achieve extraction of analytes and enrichment in an aqueous-aqueous single-drop microextraction system. In this study, we proposed a pH-dependent polydopamine (PDA)-coated vesicle/Fe3O4 magnetic aqueous-aqueous in a single-drop microreactor (SDMR) for the direct fluorescence detection of glutathione S-transferase (GST), a metabolic enzyme involved with crucial biological processes, in biological samples. After extracting and enriching the GST target from an aqueous-aqueous single-drop interface, the extraction process was conducted rapidly in 6 s in the SDMR system. The GST was first extracted from the sample solution via the GST-Aptamer on the polydopamine-coated vesicle/Fe3O4 nanospheres (Fe3O4@PDA@GST-Aptamer). Then, as the pH changed from weakly acidic to weakly alkaline in the SDMR system, the GST and GST-Aptamer were released from Fe3O4@PDA@GST-Aptamer nanospheres and captured by polydiacetylene vesicles via the capture probe. These changes altered the effective conjugation length and angle of the vesicle trunk, generating a highly enhanced fluorescence signal. This not only achieved the purpose of target enrichment but also reduced interferences posed by matrix effects. The approach can be used for the direct detection of GST in genuine urine and blood without any sample pretreatment. The linear range was 0.005 to 0.5 µg/mL, and the limit of detection was 0.834 ng/mL. The recoveries of GST in genuine blood samples ranged from 90.8 to 108.0% and in urine from 91.6 to 102.8%. The method has the capability of handling complex samples directly by enabling microextraction in an aqueous-aqueous single-drop system.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microextração em Fase Líquida / Imersão Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microextração em Fase Líquida / Imersão Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de publicação: Estados Unidos