Your browser doesn't support javascript.
loading
Radiation dose aspects and establishment of diagnostic reference levels for90Y radioembolisation during angiographic procedure.
Opitz, Marcel; Zensen, Sebastian; Ludwig, Johannes Maximilian; Weber, Manuel; Alatzides, Georgios; Seifert, Robert; Grüneisen, Johannes; Theysohn, Jens Matthias; Bos, Denise; Schaarschmidt, Benedikt Michael.
Afiliação
  • Opitz M; Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany.
  • Zensen S; Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany.
  • Ludwig JM; Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany.
  • Weber M; Department of Nuclear Medicine, University Hospital Essen, Essen, Germany.
  • Alatzides G; West German Cancer Center, University Hospital Essen, Essen, Germany.
  • Seifert R; German Cancer Consortium (DKTK), University Hospital Essen, Essen, Germany.
  • Grüneisen J; Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany.
  • Theysohn JM; Department of Nuclear Medicine, University Hospital Essen, Essen, Germany.
  • Bos D; West German Cancer Center, University Hospital Essen, Essen, Germany.
  • Schaarschmidt BM; German Cancer Consortium (DKTK), University Hospital Essen, Essen, Germany.
J Radiol Prot ; 42(3)2022 09 28.
Article em En | MEDLINE | ID: mdl-36067741
90Y radioembolisation (RE) is an angiographic procedure used in patients with both primary and secondary hepatic malignancies. Local tumour control can be achieved by short range tumour irradiation by the regional intra-arterial administration of glass or resin microspheres loaded with 90yttrium that accumulate in the tumorous tissue. The aim of this study was to investigate the radiation exposure of RE and to establish a local diagnostic reference level (DRL). In this retrospective study, dose data from 397 procedures in 306 patients (mean age 67.4 ± 10.6 years, 82 female) who underwent RE between 06/2017 and 01/2022 using one of two different angiography systems were analysed. DRL was set as the 75th percentile of the dose distribution. In the overall population, dose area product (DAP) (median (interquartile range, IQR)) was 26 Gy cm2(IQR 12-50) with a median fluoroscopy time (FT) of 4.5 min (IQR 2.9-8.0). FT and DAP increased significantly with the number of infusion positions (median, IQR): one position 23 Gy cm2(12-46), two positions 33 Gy cm2(14-60), three positions 50 Gy cm2(24-82) (p< 0.0001). Local DRL is 47 Gy cm2for RE and 111 Gy cm2for RE with additional embolisation. Radiation exposure and FT are significantly higher with increasing number of infusion positions as well as additional embolisation. Our established DRLs for RE may serve as a benchmark for dose optimisation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia / Níveis de Referência de Diagnóstico Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Middle aged Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia / Níveis de Referência de Diagnóstico Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Middle aged Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Reino Unido