Your browser doesn't support javascript.
loading
Gluclas: A software for computer-aided modulation of glucose infusion in glucose clamp experiments.
Pavan, J; Dalla Man, C; Herzig, D; Bally, L; Del Favero, S.
Afiliação
  • Pavan J; Department of Information Engineering, University of Padova, Padova, Italy.
  • Dalla Man C; Department of Information Engineering, University of Padova, Padova, Italy.
  • Herzig D; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
  • Bally L; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
  • Del Favero S; Department of Information Engineering, University of Padova, Padova, Italy. Electronic address: sdelfave@dei.unipd.it.
Comput Methods Programs Biomed ; 225: 107104, 2022 Oct.
Article em En | MEDLINE | ID: mdl-36088892
BACKGROUND AND OBJECTIVE: The glucose clamp (GC) is an experimental technique for assessing several aspects of glucose metabolism. In these experiments, investigators face the non-trivial challenge of accurately adjusting the rate of intravenous glucose infusion to drive subjects' blood glucose (BG) concentration towards a desired plateau level. In this work we present Gluclas, an open-source software to support researchers in the modulation of glucose infusion rate (GIR) during GC experiments. METHODS: Gluclas uses a proportional-integrative-derivative controller to provide GIR suggestions based on BG measurements. The controller embeds an anti-wind-up scheme to account for actuator physical limits and suitable corrections of control action to accommodate for possible sampling jitter due to manual measurement and actuation. The software also provides a graphic user interface to increase its usability. A preliminary validation of the controller is performed for different clamp scenarios (hyperglycemic, euglycemic, hypoglycemic) on a simulator of glucose metabolism in healthy subjects, which also includes models of measurement error and sampling delay for increased realism. In silico trials are performed on 50 virtual subjects. We also report the results of the first in-vivo application of the software in three subjects undergoing a hypoglycemic clamp. RESULTS: In silico, during the plateau period, the coefficient of variation (CV) is in median below 5% for every protocol, with 5% being considered the threshold for sufficient quality. In terms of median [5th percentile, 95th percentile], average BG level during the plateau period is 12.18 [11.58 - 12.53] mmol/l in the hyperglycemic clamp (target: 12.4 mmol/), 4.92 [4.51 - 5.14] mmol/l in the euglycemic clamp (target: 5.5 mmol/) and 2.38 [2.33 - 2.64] in the hypoglycemic clamp (target: 2.5 mmol/). Results in vivo are consistent with those obtained in silico during the plateau period: average BG levels are between 2.56 and 2.68 mmol/l (target: 2.5 mmol/l); CV is below 5% for all three experiments. CONCLUSIONS: Gluclas offered satisfactory control for tested GC protocols. Although its safety and efficacy need to be further validated in vivo, this preliminary validation suggest that Gluclas offers a reliable and non-expensive solution for reducing investigator bias and improving the quality of GC experiments.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Glucose Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Comput Methods Programs Biomed Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Irlanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Glucose Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Comput Methods Programs Biomed Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Irlanda