Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review.
Qin, Jiaxing Jason; Indja, Ben; Gholipour, Alireza; Gök, Mustafa; Grieve, Stuart M.
Afiliação
  • Qin JJ; Imaging and Phenotyping Laboratory, Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia.
  • Indja B; Faculty of Medicine and Health, University of Sydney, Sydney, NSW 2006, Australia.
  • Gholipour A; Imaging and Phenotyping Laboratory, Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia.
  • Gök M; Faculty of Medicine and Health, University of Sydney, Sydney, NSW 2006, Australia.
  • Grieve SM; Imaging and Phenotyping Laboratory, Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia.
J Cardiovasc Dev Dis ; 9(9)2022 Sep 12.
Article em En | MEDLINE | ID: mdl-36135449
ABSTRACT
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as "highly clinically applicable". There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Systematic_reviews Idioma: En Revista: J Cardiovasc Dev Dis Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Austrália