Determination of thiram residues in fresh water using flow injection diperiodatonickelate(IV)-quinine chemiluminescence detection.
Luminescence
; 37(12): 2041-2049, 2022 Dec.
Article
em En
| MEDLINE
| ID: mdl-36150887
ABSTRACT
This study developed a simple flow injection (FI) method based on diperiodatonickelate(IV)-sulfuric acid reaction using chemiluminescence (CL) detection for the determination of thiram (THI) fungicide in fresh water using quinine as the sensitizer. The possible mechanism of the CL reaction was described using UV-Vis. absorption and CL spectra. Experimental variables were optimized by applying a univariate approach, and a linear calibration curve was obtained in the range of 1.0 × 10-3 -2.0 mg L-1 (R2 = 0.9994, n = 9) with a limit of detection of 5.0 × 10-4 mg L-1 (S/N = 3) and an injection throughput of 200 h-1 . This approach was successfully applied to determine THI in fresh water by using solid-phase extraction and achieved a good recovery rate of 94%-110% with a relative standard deviation of 1.9%-3.7% (n = 4). The results obtained were compared with the reported FI-CL and high-performance liquid chromatography-ultraviolet methods, and the three methods did not differ significantly at the 95% confidence limit.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Tiram
/
Análise de Injeção de Fluxo
Tipo de estudo:
Diagnostic_studies
Idioma:
En
Revista:
Luminescence
Assunto da revista:
BIOFISICA
/
BIOQUIMICA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
Paquistão