Your browser doesn't support javascript.
loading
Inter-rater reliability of the measurement of diaphragmatic excursion and fraction of diaphragmatic thickening by ultrasonography in healthy volunteers.
Wilches-Luna, E C; Pabón-Muñoz, F E; Arias-Campo, J M; Caballero-Lozada, A F.
Afiliação
  • Wilches-Luna EC; Escuela de Rehabilitación Humana, Facultad de Salud, Universidad del Valle, Cali, Colombia. Electronic address: esther.wilches@correounivalle.edu.co.
  • Pabón-Muñoz FE; Departamento de Anestesiología y Reanimación, Hospital Universitario del Valle, Universidad del Valle, Cali, Colombia.
  • Arias-Campo JM; Escuela de Rehabilitación Humana, Facultad de Salud, Universidad del Valle, Cali, Colombia.
  • Caballero-Lozada AF; Departamento de Anestesiología y Reanimación, Hospital Universitario del Valle, Universidad del Valle, Cali, Colombia.
Rev Esp Anestesiol Reanim (Engl Ed) ; 69(9): 536-543, 2022 11.
Article em En | MEDLINE | ID: mdl-36241512
ABSTRACT
BACKGROUND AND

OBJECTIVE:

To determine the inter-rater reliability in the ultrasonographic (US) measurement of the diaphragmatic excursion (DE) and the diaphragm thickness fraction (DTF) performed by non-medical health professionals in healthy people. PARTICIPANTS AND

METHODS:

Prospective observational study in a third level hospital in Cali, Colombia. Measurements were made to 30 healthy volunteers chosen by convenience sampling, without a history of lung diseases, with ages between 18-60 years. A pilot test was previously carried out with 8 healthy volunteers. US measurements of DE, and DTF were based on previously published protocols. Each assessor independently observed several cycles of normal quiet breathing for 3min to establish a baseline. The Intraclass Correlation Index (ICC) was used to evaluate the inter-rater reliability in the measurements of DE and DTF, with 95% confidence intervals and a p<0.05.

RESULTS:

Substantial agreement was identified in the measurement of DE in the splenic and hepatic windows because the ICC was greater than 0.6 (p<0.05). The measurement of the DTF in the hepatic window showed slight agreement in both 2D and M modes (p>0.05). In the splenic window, the measurement of the DTF in the 2D mode was found to be moderate agreement and for the M mode a slight agreement was found (p>0.05).

CONCLUSIONS:

The diaphragmatic US constitutes a reproducible method with acceptable inter-rater reliability for the measurement of inspiratory/expiratory thickness, and with little reliability for the measurement of DTF.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diafragma / Expiração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Humans / Middle aged Idioma: En Revista: Rev Esp Anestesiol Reanim (Engl Ed) Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diafragma / Expiração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Humans / Middle aged Idioma: En Revista: Rev Esp Anestesiol Reanim (Engl Ed) Ano de publicação: 2022 Tipo de documento: Article