Your browser doesn't support javascript.
loading
Evaluation of the cerebrovascular reactivity in patients with Moyamoya Angiopathy by use of breath-hold fMRI: investigation of voxel-wise hemodynamic delay correction in comparison to [15O]water PET.
Zerweck, Leonie; Hauser, Till-Karsten; Roder, Constantin; Blazhenets, Ganna; Khan, Nadia; Ernemann, Ulrike; Meyer, Philipp T; Klose, Uwe.
Afiliação
  • Zerweck L; Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tuebingen, Germany. Leonie.Zerweck@med.uni-tuebingen.de.
  • Hauser TK; Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tuebingen, Germany.
  • Roder C; Department of Neurosurgery, University Hospital Tuebingen, Tuebingen, Germany.
  • Blazhenets G; Department of Nuclear Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Khan N; Department of Neurosurgery, University Hospital Tuebingen, Tuebingen, Germany.
  • Ernemann U; Moyamoya Center, University Children's Hospital Zurich, Zurich, Switzerland.
  • Meyer PT; Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tuebingen, Germany.
  • Klose U; Department of Nuclear Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Neuroradiology ; 65(3): 539-550, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36434312
ABSTRACT

PURPOSE:

Patients with Moyamoya Angiopathy (MMA) require hemodynamic assessment to evaluate the risk of stroke. Hemodynamic evaluation by use of breath-hold-triggered fMRI (bh-fMRI) was proposed as a readily available alternative to the diagnostic standard [15O]water PET. Recent studies suggest voxel-wise hemodynamic delay correction in hypercapnia-triggered fMRI. The aim of this study was to evaluate the effect of delay correction of bh-fMRI in patients with MMA and to compare the results with [15O]water PET.

METHODS:

bh-fMRI data sets of 22 patients with MMA were evaluated without and with voxel-wise delay correction within different shift ranges and compared to the corresponding [15O]water PET data sets. The effects were evaluated combined and in subgroups of data sets with most severely impaired CVR (apparent steal phenomenon), data sets with territorial time delay, and data sets with neither steal phenomenon nor delay between vascular territories.

RESULTS:

The study revealed a high mean cross-correlation (r = 0.79, p < 0.001) between bh-fMRI and [15O]water PET. The correlation was strongly dependent on the choice of the shift range. Overall, no shift range revealed a significantly improved correlation between bh-fMRI and [15O]water PET compared to the correlation without delay correction. Delay correction within shift ranges with positive high high cutoff revealed a lower agreement between bh-fMRI and PET overall and in all subgroups.

CONCLUSION:

Voxel-wise delay correction, in particular with shift ranges with high cutoff, should be used critically as it can lead to false-negative results in regions with impaired CVR and a lower correlation to the diagnostic standard [15O]water PET.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Doença de Moyamoya Limite: Humans Idioma: En Revista: Neuroradiology Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Doença de Moyamoya Limite: Humans Idioma: En Revista: Neuroradiology Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha