Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in patients with axial hyperopia.
Bansal, Muskaan; Thakur, Anchal; Gupta, Gaurav; Jurangal, Ajay; Khanna, Rahul; Malhotra, Chintan; Gupta, Amit; Jain, Arun Kumar.
Afiliação
  • Bansal M; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Thakur A; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Gupta G; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Jurangal A; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Khanna R; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Malhotra C; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Gupta A; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Jain AK; Department of Ophthalmology, Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Indian J Ophthalmol ; 70(12): 4295-4299, 2022 12.
Article em En | MEDLINE | ID: mdl-36453332
ABSTRACT

Purpose:

This study was conducted to evaluate the accuracy of intraoperative aberrometry (IA) in intraocular lens (IOL) power calculation and compare it with conventional IOL formulas.

Methods:

This was a prospective case series. Eyes with visually significant cataract and axial hyperopia (AL <22.0 mm) underwent IA-assisted phacoemulsification with posterior chamber IOL (Alcon AcrySof IQ). Postoperative spherical equivalent (SE) was compared with predicted SE to calculate the outcomes with different formulas (SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal Ⅱ and Hill-RBF). Accuracy of intraoperative aberrometer was compared with other formulas in terms of mean absolute prediction error (MAE), percentage of patients within 0.5 D and 1 D of their target, and percentage of patients going into hyperopic shift.

Results:

Sixty-five eyes (57 patients) were included. In terms of MAE, both Hoffer Q (MAE = 0.30) and IA (MAE = 0.32) were significantly better than Haigis, SRK/T, and Barrett Universal Ⅱ (P < 0.05). Outcomes within ±0.5 D of the target were maximum with Hoffer Q (80%), superior to IA (Hoffer Q > IA > Holladay 2 > Hill-RBF > Haigis > SRK/T > Barrett Universal Ⅱ). Hoffer Q resulted in minimum hyperopic shift (30.76%) followed by Hill-RBF (38.46%), Holladay 2 (38.46%), Haigis (43.07%), and then IA (46.15%), SRK/T (50.76%) and Barrett Universal Ⅱ (53.84%).

Conclusion:

IA was more effective (statistically significant) in predicting IOL power than Haigis, SRK/T, and Barrett Universal Ⅱ although it was equivalent to Hoffer Q. Hoffer Q was superior to all formulas in terms of percentage of patients within 0.5 D of their target refractions and percentage of patients going into hyperopic shift.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperopia / Lentes Intraoculares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperopia / Lentes Intraoculares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia