Haemodynamic and clinical variables after surgical systemic to pulmonary artery shunt placement versus arterial ductal stenting.
Sheth, Saloni P; Loomba, Rohit S.
Afiliação
  • Sheth SP; Division of Pediatric Cardiology, Advocate Children's Hospital, Oak Lawn, IL, USA.
  • Loomba RS; Division of Pediatric Cardiology, Advocate Children's Hospital, Oak Lawn, IL, USA.
Cardiol Young ; 33(10): 2060-2065, 2023 Oct.
Article em En | MEDLINE | ID: mdl-36519418
ABSTRACT

BACKGROUND:

Transcatheter stenting of the arterial duct is an alternative to surgical systemic to pulmonary artery shunt in neonates with parallel circulation. The current study compares haemodynamic and laboratory values in these patients for the first 48 hours after either intervention.

METHODS:

Neonates with ductal dependent pulmonary blood flow who underwent surgical shunt placement or catheter-based arterial ductal stent placement between January 2013 and January 2022 were identified. Haemodynamic variables included heart rate, blood pressure, near infrared spectroscopy, central venous pressure, vasoactive inotropic score, and arterial saturation. Laboratory variables collected included blood urea nitrogen, serum creatinine, and serum lactate. Variables were collected at baseline, upon post-procedural admission, 6 hours after admission, 12 hours after admission, and 48 hours after admission. Secondary outcomes included post-procedural mechanical ventilation duration, post-procedural hospital length of stay, need for reintervention, need for extracorporeal membrane oxygenation, cardiac arrest, and inpatient mortality.

RESULTS:

Of the 52 patients included, 38 (73%) underwent shunt placement while 14 (27%) underwent a stent placement. Heart rates, renal oxygen extraction ratio, and cerebral oxygen extraction ratio were significantly lower in the stent group (p = <0.01, 0.01, and < 0.01, respectively).Haemoglobin and vasoactive inotropic scores were significantly lower in the stent group (p = <0.01, <0.01, respectively). The stent group had increased risk for cardiac arrest (p = 0.04).

CONCLUSION:

Patients who undergo arterial ductal stent placement have lower heart rates, haemoglobin, renal oxygen extraction ratio, cerebral oxygen extraction ratio, and vasoactive inotropic score in the first 48 hours post-procedure compared to patients with shunt placement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimento de Blalock-Taussig / Parada Cardíaca / Cardiopatias Congênitas Tipo de estudo: Prognostic_studies Limite: Humans / Infant / Newborn Idioma: En Revista: Cardiol Young Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimento de Blalock-Taussig / Parada Cardíaca / Cardiopatias Congênitas Tipo de estudo: Prognostic_studies Limite: Humans / Infant / Newborn Idioma: En Revista: Cardiol Young Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos