Your browser doesn't support javascript.
loading
Effects of Radiant Floor Heating Integrated with Natural Ventilation on Flow and Dispersion in a Newly Decorated Residence.
Cui, Peng-Yi; Wang, Jia-Qi; Yang, Feng; Zhao, Qing-Xia; Huang, Yuan-Dong; Yang, Yong; Tao, Wen-Quan.
Afiliação
  • Cui PY; School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Wang JQ; School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Yang F; School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Zhao QX; School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Huang YD; School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Yang Y; College of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou 215000, China.
  • Tao WQ; School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Article em En | MEDLINE | ID: mdl-36554770
ABSTRACT
To date, few studies have been conducted on the characteristics of flow and dispersion caused by indoor radiant floor heating integrated with natural ventilation. In this study, we employed reduced-scale numerical models validated by wind-tunnel experiments to investigate the influence of radiant floor heating integrated with natural ventilation on airflow, heat transfer, and pollutant dispersion within an isolated building. The Richardson number (Ri) was specified to characterize the interaction between the inflow inertia force and the buoyancy force caused by radiant floor heating. Several Ri cases from 0 to 26.65, coupled with cross- or single-sided ventilation, were considered. Model validation showed that the numerical model coupled with the RNG k-ε model was able to better predict the indoor buoyant flow and pollutant dispersion. The results showed that the similarity criterion of Ri equality should be first satisfied in order to study indoor mixed convection using the reduced-scale model, followed by Re-independence. For cross-ventilation, when Ri < 5.31, the incoming flow inertia force mainly dominates the indoor flow structure so that the ACH, indoor temperature, and pollutant distributions remain almost constant. When Ri > 5.31, the thermal buoyancy force becomes increasingly important, causing significant changes in indoor flow structures. However, for single-sided ventilation, when Ri > 5.31 and continues to increase, the buoyancy force mainly dominates the indoor flow structure, causing a significant increase in ACH, thus reducing the indoor average temperature and pollutant accumulation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Ambientais Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Ambientais Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China