Your browser doesn't support javascript.
loading
Protocol for mouse optogenetic fMRI at ultrahigh magnetic fields.
Shim, Hyun-Ji; Im, Geun Ho; Jung, Won Beom; Moon, Hyun Seok; Dinh, Thi Ngoc Anh; Lee, Jeong-Yun; Kim, Seong-Gi.
Afiliação
  • Shim HJ; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea. Electronic address: hyunjishim@skku.edu.
  • Im GH; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea.
  • Jung WB; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea.
  • Moon HS; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.
  • Dinh TNA; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.
  • Lee JY; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea.
  • Kim SG; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon 16419, Republic of Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea. Electronic address: seonggikim@skku.edu.
STAR Protoc ; 3(4): 101846, 2022 12 16.
Article em En | MEDLINE | ID: mdl-36595930
Mouse optogenetic functional magnetic resonance imaging (opto-fMRI) is critical for linking genes and functions and for mapping cell-type-specific neural circuits in the whole brain. Herein, we describe how opto-fMRI images can be reliably obtained in anesthetized mice with minimal distortions at ultrahigh magnetic fields. The protocol includes surgical and anesthesia procedures, animal cradle modification, animal preparation and setup, animal physiology maintenance, and pilot fMRI scanning. This protocol will enable reproducible mouse opto-fMRI experiments. For complete details on the use and execution of this protocol, please refer to Jung et al. (2021),1 Jung et al. (2022),2 and Moon et al. (2021).3.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Optogenética Limite: Animals Idioma: En Revista: STAR Protoc Ano de publicação: 2022 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Optogenética Limite: Animals Idioma: En Revista: STAR Protoc Ano de publicação: 2022 Tipo de documento: Article País de publicação: Estados Unidos