The use of smartwatch electrocardiogram beyond arrhythmia detection.
Strik, Marc; Ploux, Sylvain; Weigel, Daniel; van der Zande, Joske; Velraeds, Anouk; Racine, Hugo-Pierre; Ramirez, F Daniel; Haïssaguerre, Michel; Bordachar, Pierre.
Afiliação
  • Strik M; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France. Electronic address: marc.strik@chu-bordeaux.fr.
  • Ploux S; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France.
  • Weigel D; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France; Maastricht University, Maastricht, the Netherlands.
  • van der Zande J; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France; Twente University, Twente, the Netherlands.
  • Velraeds A; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France; Twente University, Twente, the Netherlands.
  • Racine HP; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France.
  • Ramirez FD; Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
  • Haïssaguerre M; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France.
  • Bordachar P; Bordeaux University Hospital (CHU), Cardio-Thoracic Unit, F-33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, F-33600 Pessac- Bordeaux, France.
Trends Cardiovasc Med ; 34(3): 174-180, 2024 Apr.
Article em En | MEDLINE | ID: mdl-36603673
ABSTRACT
The adoption of wearables in medicine has expanded worldwide with a rapidly growing number of consumers and new features capable of real-time monitoring of health parameters such as the ability to record and transmit a single-lead electrocardiogram (ECG). Smartwatch ECGs are increasingly used but current smartwatches only screen for atrial fibrillation (AF). Most of the literature has focused on analyzing the smartwatch ECG accuracy for the detection of AF or other tachycardias. As with the conventional ECG, this tool may be used for many more purposes than only detection of AF. The objectives of this review are to describe the published literature regarding the accuracy and clinical value of recording a smartwatch ECG in other situations than diagnosis of tachycardia and discuss possible techniques to optimize the diagnostic yield.