Your browser doesn't support javascript.
loading
Automatic segmentation and measurement of pressure injuries using deep learning models and a LiDAR camera.
Liu, Tom J; Wang, Hanwei; Christian, Mesakh; Chang, Che-Wei; Lai, Feipei; Tai, Hao-Chih.
Afiliação
  • Liu TJ; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan.
  • Wang H; Division of Plastic Surgery, Department of Surgery, Fu Jen Catholic University Hospital, Fu Jen Catholic University, New Taipei City, Taiwan.
  • Christian M; Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan.
  • Chang CW; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan.
  • Lai F; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan.
  • Tai HC; Division of Plastic Reconstructive and Aesthetic Surgery, Department of Surgery, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
Sci Rep ; 13(1): 680, 2023 01 13.
Article em En | MEDLINE | ID: mdl-36639395
ABSTRACT
Pressure injuries are a common problem resulting in poor prognosis, long-term hospitalization, and increased medical costs in an aging society. This study developed a method to do automatic segmentation and area measurement of pressure injuries using deep learning models and a light detection and ranging (LiDAR) camera. We selected the finest photos of patients with pressure injuries, 528 in total, at National Taiwan University Hospital from 2016 to 2020. The margins of the pressure injuries were labeled by three board-certified plastic surgeons. The labeled photos were trained by Mask R-CNN and U-Net for segmentation. After the segmentation model was constructed, we made an automatic wound area measurement via a LiDAR camera. We conducted a prospective clinical study to test the accuracy of this system. For automatic wound segmentation, the performance of the U-Net (Dice coefficient (DC) 0.8448) was better than Mask R-CNN (DC 0.5006) in the external validation. In the prospective clinical study, we incorporated the U-Net in our automatic wound area measurement system and got 26.2% mean relative error compared with the traditional manual method. Our segmentation model, U-Net, and area measurement system achieved acceptable accuracy, making them applicable in clinical circumstances.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aprendizado Profundo Tipo de estudo: Guideline / Observational_studies Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aprendizado Profundo Tipo de estudo: Guideline / Observational_studies Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM