Your browser doesn't support javascript.
loading
Ultrasound Fusion-Guided Core Needle Biopsy for Deep Head and Neck Space Lesions: Technical Feasibility, Histopathologic Yield, and Safety.
Li, X; Li, J; Zheng, N; Hu, H; Xie, X; Huang, G.
Afiliação
  • Li X; From the Department of Medical Ultrasonics (X.L., H.H., X.X., G.H.), Institute of Diagnostic and Interventional Ultrasound.
  • Li J; Department of Otorhinolaryngology (J.L., N.Z.), The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
  • Zheng N; Department of Otorhinolaryngology (J.L., N.Z.), The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
  • Hu H; From the Department of Medical Ultrasonics (X.L., H.H., X.X., G.H.), Institute of Diagnostic and Interventional Ultrasound.
  • Xie X; From the Department of Medical Ultrasonics (X.L., H.H., X.X., G.H.), Institute of Diagnostic and Interventional Ultrasound.
  • Huang G; From the Department of Medical Ultrasonics (X.L., H.H., X.X., G.H.), Institute of Diagnostic and Interventional Ultrasound huanggl9@mail.sysu.edu.cn.
AJNR Am J Neuroradiol ; 44(2): 180-185, 2023 02.
Article em En | MEDLINE | ID: mdl-36702505
ABSTRACT
BACKGROUND AND

PURPOSE:

Ultrasound is generally considered to have a minor role in guiding biopsies for deep head and neck space lesions. However, the ultrasound fusion technique may have the potential to change this opinion. This study evaluated the feasibility, histopathologic yield, and safety of ultrasound fusion-guided core needle biopsies for deep head and neck space lesions. MATERIALS AND

METHODS:

From March 2021 to April 2022, patients with primary deep head and neck space lesions were prospectively included in this study. Ultrasound fusion was performed with contemporaneous CT, MR imaging, or PET/CT studies, and ultrasound fusion-guided core needle biopsy was performed by using a Micro-Convex probe via 4 different needle approaches. Feasibility, histopathologic results, and biopsy-related complications were observed. Descriptive statistics were applied.

RESULTS:

Ultrasound-guided biopsy was feasible in all 16 patients (11 women and 5 men; mean age 46 [SD, 16] years; range, 16-76 years). The lesions were located in the parapharyngeal space, infratemporal fossa, and skull base, with a median diameter of 3.8 cm (range, 2.2-6.5 cm). An adequate and definite histopathologic yield was obtained in 15/16 (93.8%) patients; among them, 4/15 lesions (26.7%) were malignant, and 11/15 (73.6%) were benign. No major complications occurred. Minor complications were noted in 2 of the 16 (12.5%) patients (self-limiting inflammation in 1 and bleeding in 1).

CONCLUSIONS:

This study demonstrates that ultrasound fusion-guided biopsy of deep head and neck space lesions is feasible and safe, with a high histopathologic yield.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia Guiada por Imagem / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia Guiada por Imagem / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2023 Tipo de documento: Article