Your browser doesn't support javascript.
loading
Medical gamma cameras in radiological emergency preparedness: determination of calibration factors and MDA for the GE Discovery NM/CT 670 Pro.
Hjellström, Martin; Isaksson, Mats.
Afiliação
  • Hjellström M; Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Isaksson M; Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
J Radiol Prot ; 43(1)2023 02 23.
Article em En | MEDLINE | ID: mdl-36749985
ABSTRACT
A survey was performed of the available gamma camera models and whole-body counters (WBCs) in Sweden, revealing that there are about 75 gamma cameras and 15 WBCs currently in operation in Sweden. One of the most common gamma camera models (GE Discovery NM/CT 670 Pro), with the collimators removed, was calibrated for152Eu,137Cs,60Co and40K in three different measurement geometries (supine, close-up sitting and distant sitting) for six different phantom sizes (12-110 kg). Minimum detectable activities (MDAs) were calculated for the gamma camera and a typical WBC, both at the Sahlgrenska University Hospital in Gothenburg, Sweden. An energy window of 30-510 keV was used to calibrate the gamma camera. The calibration factors for this gamma camera for supine and close-up sitting geometry, including all phantom sizes, were 138-208 cps kBq-1for152Eu, 63-83 cps kBq-1for137Cs and 99-126 cps kBq-1for60Co; the MDAs were 50-73 Bq for152Eu, 125-198 Bq for137Cs and 83-105 Bq for60Co. The International Commission on Radiological Protection dose coefficients for members of the public were used to calculate the committed effective doses (CEDs) corresponding to the MDAs, showing that CEDs down to a fewµSv can be estimated with this gamma camera for the inhalation of aerosols of absorption type M. The distant sitting geometry was used to enable the estimation of higher contamination levels, and a hypothetical maximum CED was calculated. This was shown to be 256-2000 mSv, depending on the radionuclide and phantom size. However, further investigations are needed into the dead time losses for higher activity levels for the radionuclides studied. The results show that the use of gamma cameras for radiological triage and, in some cases, to estimate the internal activity of relevant radionuclides in radiological and nuclear events, is feasible.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Câmaras gama / Defesa Civil Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suécia País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Câmaras gama / Defesa Civil Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suécia País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM