Your browser doesn't support javascript.
loading
Comparison of Radiation Response between 2D and 3D Cell Culture Models of Different Human Cancer Cell Lines.
Raitanen, Julia; Barta, Bernadette; Hacker, Marcus; Georg, Dietmar; Balber, Theresa; Mitterhauser, Markus.
Afiliação
  • Raitanen J; Ludwig Boltzmann Institute Applied Diagnostics, 1090 Vienna, Austria.
  • Barta B; Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, 1090 Vienna, Austria.
  • Hacker M; Vienna Doctoral School of Chemistry (DoSChem), University of Vienna, 1090 Vienna, Austria.
  • Georg D; Institute of Inorganic Chemistry, Faculty of Chemistry, University of Vienna, 1090 Vienna, Austria.
  • Balber T; Ludwig Boltzmann Institute Applied Diagnostics, 1090 Vienna, Austria.
  • Mitterhauser M; Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, 1090 Vienna, Austria.
Cells ; 12(3)2023 01 18.
Article em En | MEDLINE | ID: mdl-36766704
ABSTRACT
Radiation therapy is one of the most effective tools in cancer therapy. However, success varies individually, necessitating improved understanding of radiobiology. Three-dimensional (3D) tumor spheroids are increasingly gaining attention, being a superior in vitro cancer model compared to 2D cell cultures. This in vitro study aimed at comparing radiation responses in 2D and 3D cell culture models of different human cancer cell lines (PC-3, LNCaP and T-47D) irradiated with varying doses (1, 2, 4, 6, 8 or 20 Gy) of X-ray beams. Radiation response was analyzed by growth analysis, various cell viability assays (e.g., clonogenic assay, resazurin assay) and amount of DNA damage (γH2AX Western Blot). Results showed decreasing cell proliferation with the increase of radiation doses for all cell lines in monolayers and spheroids of LNCaP and T-47D. However, significantly lower radiosensitivity was detected in spheroids, most pronounced in PC-3, evincing radiation resistance of PC-3 spheroids up to 8 Gy and significant growth inhibition only by a dose escalation of 20 Gy. Cell line comparison showed highest radiosensitivity in LNCaP, followed by T-47D and PC-3 in 2D, whereas, in 3D, T-47D showed highest sensitivity. The results substantiate the significant differences in radiobiological response to X-rays between 2D and 3D cell culture models.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Limite: Humans Idioma: En Revista: Cells Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Limite: Humans Idioma: En Revista: Cells Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria
...