Your browser doesn't support javascript.
loading
Developing an AI-assisted planning pipeline for hippocampal avoidance whole brain radiotherapy.
Lin, Chih-Yuan; Chou, Lin-Shan; Wu, Yuan-Hung; Kuo, John S; Mehta, Minesh P; Shiau, An-Cheng; Liang, Ji-An; Hsu, Shih-Ming; Wang, Ti-Hao.
Afiliação
  • Lin CY; Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan; Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Chou LS; Division of Radiation Oncology, Department of Oncology, Taipei Veterans General Hospital, Taipei, Taiwan.
  • Wu YH; Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan; Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan; Division of Radiation Oncology, Department of Oncology, Taipei Vetera
  • Kuo JS; Neuroscience and Brain Disease Center, China Medical University, Taichung, Taiwan; Graduate Institute of Biomedical Sciences, China Medical University, Taichung, Taiwan; Department of Neurosurgery, Dell Medical School, The University of Texas at Austin, Austin, TX, USA.
  • Mehta MP; Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida, USA; Florida International University, Miami, Florida, USA.
  • Shiau AC; Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan; Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan; Department of Radiation Oncology, China Medical University Hospital, Taichung,
  • Liang JA; Department of Radiation Oncology, China Medical University Hospital, Taichung, Taiwan; Department of Medicine, China Medical University, Taichung, Taiwan.
  • Hsu SM; Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan; Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan. Electronic address: smhsu@nycu.edu.tw.
  • Wang TH; Department of Radiation Oncology, China Medical University Hospital, Taichung, Taiwan. Electronic address: thothwang@gmail.com.
Radiother Oncol ; 181: 109528, 2023 04.
Article em En | MEDLINE | ID: mdl-36773828
BACKGROUND AND PURPOSE: Hippocampal avoidance whole brain radiotherapy (HA-WBRT) is effective for controlling disease and preserving neuro-cognitive function for brain metastases. However, contouring and planning of HA-WBRT is complex and time-consuming. We designed and evaluated a pipeline using deep learning tools for a fully automated treatment planning workflow to generate HA-WBRT radiotherapy plans. MATERIALS AND METHODS: We retrospectively collected 50 adult patients who received HA-WBRT. Using RTOG- 0933 clinical trial protocol guidelines, all organs-at-risk (OARs) and the clinical target volume (CTV) were contoured by experienced radiation oncologists. A deep-learning segmentation model was designed and trained. Next, we developed a volumetric-modulated arc therapy (VMAT) auto-planning algorithm for 30 Gy in 10 fractions. Automated segmentations were evaluated using the Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance (95 % HD). Auto-plans were evaluated by the percentage of PTV volume that receives 30 Gy (V30Gy), conformity index (CI), and homogeneity index (HI) of planning target volume (PTV) and the minimum dose (D100%) and maximum dose (Dmax) for the hippocampus, Dmax for the lens, eyes, optic nerve, brain stem, and chiasm. RESULTS: We developed a deep-learning segmentation model and an auto-planning script. For the 10 cases in the independent test set, the overall average DSC and 95 % HD of contours were greater than 0.8 and less than 7 mm, respectively. All auto-plans met the RTOG- 0933 criteria. The HA-WBRT plan automatically created time was about 10 min. CONCLUSIONS: An artificial intelligence (AI)-assisted pipeline using deep learning tools can rapidly and accurately generate clinically acceptable HA-WBRT plans with minimal manual intervention and increase efficiency of this treatment for brain metastases.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radioterapia de Intensidade Modulada Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan País de publicação: Irlanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radioterapia de Intensidade Modulada Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan País de publicação: Irlanda