Your browser doesn't support javascript.
loading
Preparation and pH Detection Performance of Rosin-Based Fluorescent Polyurethane Microspheres.
Yu, Caili; Lu, Guangjie; Yan, Chengfei; Xu, Jianben; Zhang, Faai.
Afiliação
  • Yu C; College of Chemistry and Biology Engineering, Guilin University of Technology, Guilin, 541004, China.
  • Lu G; College of Chemistry and Biology Engineering, Guilin University of Technology, Guilin, 541004, China.
  • Yan C; College of Chemistry and Biology Engineering, Guilin University of Technology, Guilin, 541004, China.
  • Xu J; College of Materials Science and Engineering, Guilin University of Technology, No 12, Jiangan Road, Guilin, 541004, People's Republic of China. xujianben2014@163.com.
  • Zhang F; College of Materials Science and Engineering, Guilin University of Technology, No 12, Jiangan Road, Guilin, 541004, People's Republic of China. zhangfaai@glut.edu.cn.
J Fluoresc ; 33(4): 1593-1602, 2023 Jul.
Article em En | MEDLINE | ID: mdl-36790631
Rosin-based fluorescent polyurethane emulsion (FPU) was prepared using isophorone diisocyanate, ester of acrylic rosin and glycidyl methacrylate, 1,5-dihydroxy naphthalene (1,5-DN), and 1,4-butanediol as the raw materials. Then, rosin-based fluorescent polyurethane microspheres (FPUMs) were successfully prepared by suspension polymerization method using FPU as the main material, azodiisobutyronitrile as the initiator, and gelatin as the dispersant. FPUMs were characterized by Fourier transform infrared spectra, thermogravimetric analysis, optical microscopy, scanning electron microscopy and fluorescence spectra, and the response performance of FPUMs to pH was studied. The results showed that FPUMs were successfully prepared. With the increase of the level of 1,5-DN, the particle size of FPUMs increased gradually, and the fluorescence intensity increased first and then decreased. When the level of 1,5-DN was 3 wt.%, the average particle size was 49.3 µm, the particle distribution index (PDI) was 1.05, and the fluorescence intensity was the largest (3662 a.u.). The fluorescence intensity of FPUMs increased linearly with the decrease of pH, which can be used for pH detection in solution. Furthermore, the FPUMs exhibited good thermal stability, anti-interference and recoverability.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: Holanda