Accuracy of radiostereometric analysis using a motorized Roentgen system in a pilot study for clinical simulation.
Cao, Han.
Afiliação
  • Cao H; Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany; Department of Orthopaedic Surgery, Taizhou Second People's Hospital, 225599 Taizhou, China. Electronic address: han.cao@fau.de.
Med Eng Phys ; 111: 103929, 2023 01.
Article em En | MEDLINE | ID: mdl-36792244
Radiostereometric analysis (RSA) is routinely implemented with two paired Roentgen tubes for three-dimensional (3D) implant migration measurements. A conventional set-up of one stationary tube and one mobile could be time-consuming. Utilizing two customized ceiling-mounted tubes is normally associated with investment costs. Thus, a pilot set-up of a motorized system (single Roentgen source) for radiostereometric image acquisition may be a time-saving and space-efficient alternative. RSA using the motorized system is feasible in this study as a non-synchronized image acquisition technique, however, patient motion may occur and influence the assessment of implant migration. The phantom study aimed to assess accuracy of RSA using the motorized Roentgen system in this in vitro study. Accuracy values of translations and rotations were ±0.29 mm and ±0.48° for the single Roentgen source RSA set-up and ±0.26 mm and ±0.48° for the conventional RSA set-up. This study was also performed to simulate potential patient motion during exposure intervals between paired image acquisition. RSA using the motorized system is able to implement RSA with acceptable accuracy. In general, RSA with synchronized image acquisition is the gold standard to access in vivo implant migration with the highest accuracy. Patient motion exists in non-synchronized image acquisition techniques and results in RSA-related motion artifacts. Then we introduced what RSA-related motion artifacts are. The uniplanar calibration cage applied in the study has a few fiducial and control markers, and some of the markers were occluded in radiographs. Whereas, the number of markers in the calibration cage is correlated with accuracy of 3D implant reconstruction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Radioestereométrica Limite: Humans Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Radioestereométrica Limite: Humans Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de publicação: Reino Unido