Your browser doesn't support javascript.
loading
Separation of Hydrochloric Acid and Oxalic Acid from Rare Earth Oxalic Acid Precipitation Mother Liquor by Electrodialysis.
Zhou, Hengcheng; Ju, Peihai; Hu, Shaowei; Shi, Lili; Yuan, Wenjing; Chen, Dongdong; Wang, Yujie; Shi, Shaoyuan.
Afiliação
  • Zhou H; College of Resources and Environment, Nanchang University, Nanchang 330031, China.
  • Ju P; Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou 341119, China.
  • Hu S; Jiangxi Province Key Laboratory of Cleaner Production of Rare Earths, Ganzhou 341119, China.
  • Shi L; Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou 341119, China.
  • Yuan W; Jiangxi Province Key Laboratory of Cleaner Production of Rare Earths, Ganzhou 341119, China.
  • Chen D; Technology Center of Angang Steel Co., Ltd., Anshan 114009, China.
  • Wang Y; College of Resources and Environment, Nanchang University, Nanchang 330031, China.
  • Shi S; Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou 341119, China.
Membranes (Basel) ; 13(2)2023 Jan 27.
Article em En | MEDLINE | ID: mdl-36837666
ABSTRACT
In this study, the hydrochloric acid from rare earth oxalic acid precipitation mother liquor was separated by electrodialysis (ED) with different anion exchange membranes, including selective anion exchange membrane (SAEM), polymer alloy anion exchange membrane (PAAEM), and homogenous anion exchange membrane (HAEM). In addition to actual wastewater, nine types of simulated solutions with different concentrations of hydrochloric acid and oxalic acid were used in the experiments. The results indicated that the hydrochloric acid could be separated effectively by electrodialysis with SAEM from simulated and real rare earth oxalic acid precipitation mother liquor under the operating voltage 15 V and ampere 2.2 A, in which the hydrochloric acid obtained in the concentrate chamber of ED is of higher purity (>91.5%) generally. It was found that the separation effect of the two acids was related to the concentrations and molar ratios of hydrochloric acid and oxalic acid contained in their mixtures. The SEM images and ESD-mapping analyses indicated that membrane fouling appeared on the surface of ACS and CSE at the diluted side of the ED membrane stack when electrodialysis was used to treat the real rare earth oxalic acid precipitation mother liquor. Fe, Yb, Al, and Dy were found in the CSE membrane section, and organic compounds containing carbon and sulfur were attached to the surface of the ACS. The results also indicated that the real rare earth precipitation mother liquor needed to be pretreated before the separation of hydrochloric acid and oxalic acid by electrodialysis.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Membranes (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: CH / SUIZA / SUÍÇA / SWITZERLAND

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Membranes (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: CH / SUIZA / SUÍÇA / SWITZERLAND