A portable acetylcholinesterase-based electrochemical sensor for field detection of organophosphorus.
Wen, Long; Wang, Jianfang; Liu, Zhuoliang; Tao, Cheng-An; Rao, Jialing; Hang, Jian; Li, Yujiao.
Afiliação
  • Wen L; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Wang J; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Liu Z; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Tao CA; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Rao J; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Hang J; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
  • Li Y; College of Science, National University of Defense Technology Changsha 410073 P. R. China wangjianfang@nudt.edu.cn.
RSC Adv ; 13(10): 6389-6395, 2023 Feb 21.
Article em En | MEDLINE | ID: mdl-36874943
A portable acetylcholinesterase (AChE)-based electrochemical sensor based on a screen-printed carbon electrode (SPCE) and a miniature potentiostat was constructed for the rapid field detection of organophosphorus pesticides (OPs). Graphene (GR) and gold nanoparticles (AuNPs) were successively introduced onto SPCE for surface modification. Due to the synergistic effect of the two nanomaterials, the signal of the sensor has a significant enhancement. Take isocarbophos (ICP) as a model for chemical warfare agents (CAWs) and Ops; the SPCE/GR/AuNPs/AChE/Nafion sensor shows a wider linear range (0.1-2000 µg L-1), and a lower limit of detection (0.012 µg L-1) than SPCE/AChE/Nafion and SPCE/GR/AChE/Nafion sensors. Tests in actual fruit and tap water samples also yielded satisfactory results. Therefore, the proposed method can be used as a simple and cost-effective strategy for construction of portable electrochemical sensors for OP field detection.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: RSC Adv Ano de publicação: 2023 Tipo de documento: Article País de publicação: Reino Unido