Your browser doesn't support javascript.
loading
A robust lyophilized kit for convenient one-step formulation of [68Ga]Ga-DOTA-E-[c(RGDfK)]2 in hospital radiopharmacy for clinical PET imaging.
Das, Soumen; Sahu, Sudeep; Chakraborty, Avik; Kamaleshwaran, K K; Bannore, Trupti Upadhye; Damle, Archana; Chakravarty, Rubel; Chakraborty, Sudipta.
Afiliação
  • Das S; Radiopharmaceuticals Program, Board of Radiation and Isotope Technology, Navi Mumbai, India; Homi Bhabha National Institute, Mumbai, India.
  • Sahu S; Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India.
  • Chakraborty A; Homi Bhabha National Institute, Mumbai, India; Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India.
  • Kamaleshwaran KK; Department of Nuclear Medicine and PET, Kovai Medical Centre and Hospital, Coimbatore, India.
  • Bannore TU; Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India.
  • Damle A; Homi Bhabha National Institute, Mumbai, India; Radiation Medicine Centre, Bhabha Atomic Research Centre, Mumbai, India.
  • Chakravarty R; Homi Bhabha National Institute, Mumbai, India; Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai, India.
  • Chakraborty S; Homi Bhabha National Institute, Mumbai, India; Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai, India. Electronic address: sudipta@barc.gov.in.
Appl Radiat Isot ; 196: 110725, 2023 Jun.
Article em En | MEDLINE | ID: mdl-36878089
ABSTRACT
The present article describes the development of robust lyophilized kit for convenient formulation of [68Ga]Ga-DOTA-E-[c(RGDfK)]2 (E = glutamic acid, R = arginine, G = glycine, D = aspartic acid, f = phenylalanine, K = lysine) radiopharmaceutical for clinical use in non-invasive monitoring of malignancies overexpressing integrin αvß3 receptors. Five batches of the kit were prepared with optimized kit contents, all of which showed high 68Ga-radiolabeling yield (>98%). Pre-clinical evaluation of the [68Ga]Ga-radiotracer in SCID mice bearing FTC133 tumour exhibited significant accumulation in the tumor xenograft. Preliminary human clinical investigation carried out in a 60 year old male patient with metastatic lung cancer revealed high radiotracer uptake in the tumor along with satisfactory target to non-target contrast. The developed kit formulation also showed a long shelf-life of at least 12 months on storage at 0 °C. All these results point towards the promising attributes of the developed kit formulation for convenient preparation of [68Ga]Ga-DOTA-E-[c(RGDfK)]2 for routine clinical use.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Radioisótopos de Gálio Limite: Animals / Humans / Male / Middle aged Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Radioisótopos de Gálio Limite: Animals / Humans / Male / Middle aged Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia