Your browser doesn't support javascript.
loading
Cuff size, cuff placement, blood pressure state, and monitoring technique can influence indirect arterial blood pressure monitoring in anesthetized bats (Pteropus vampyrus).
Paranjape, Vaidehi V; Gatson, Bonnie J; Bailey, Kate; Wellehan, James F X.
Afiliação
  • Paranjape VV; Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA.
  • Gatson BJ; Safe Harbor Veterinary Anesthesia Support LLC, Gainesville, FL.
  • Bailey K; United Veterinary Care, Palm Beach Gardens, FL.
  • Wellehan JFX; Zoological Medicine Service, Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL.
Am J Vet Res ; 84(5)2023 May 01.
Article em En | MEDLINE | ID: mdl-36921023
OBJECTIVE: Evaluate agreement between 2 non-invasive blood pressure (NIBP) techniques and invasive arterial blood pressure (IBP) in anesthetized bats using various cuff sizes and cuff positioning while also evaluating its performance during hypertension and hypotension. ANIMALS: 8 bats (1.1 ± 0.2 kg). PROCEDURES: Bats were anesthetized with isoflurane in oxygen. NIBP was measured using oscillometric (NIBP-O) and Doppler (NIBP-D) techniques in the pectoral limb (PEC) and pelvic limbs (PEL) using 3 cuff sizes (1, 2, and 3). NIBP measurements were compared with IBP; systolic (SAPinvasive), mean (MAPinvasive), and diastolic arterial blood pressure (DAPinvasive) during normotension, hypertension, and hypotension. Hypotension was induced with isoflurane (3.8 ± 1.2%) and hypertension with norepinephrine (3 ± 0.5 µg/kg/min). Data analysis included Bland-Altman analyses and 3-way ANOVA. Results were reported as mean bias (95% CI). RESULTS: NIBP-O monitor reported 29% errors, and experienced more failures with hypertension, cuff placement on PEC, and using a size 1 cuff. Across states, an agreement between NIBP-D and MAPinvasive with cuff 2 on PEL (-3 mmHg [-8, 1]), and NIBP-D and SAPinvasive with cuff 3 on PEC (2 mmHg [-5, 9 mmHg]) was achieved. NIBP-D over-estimated SAPinvasive and MAPinvasive during hypertension in both limbs with cuffs 1 and 2. Except during hypotension, NIBP-O underestimated MAPinvasive and DAPinvasive using a size 2 cuff on PEL. CLINICAL RELEVANCE: In anesthetized bats, NIBP-O is unreliable for estimating IBP. NIBP-D shows acceptable agreement with MAPinvasive with cuff size 2 on PEL, and with SAPinvasive with cuff size 3 on PEC across a wide range of IBP values.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Quirópteros / Hipertensão / Hipotensão / Isoflurano Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2023 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Quirópteros / Hipertensão / Hipotensão / Isoflurano Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2023 Tipo de documento: Article País de publicação: Estados Unidos