Your browser doesn't support javascript.
loading
Relationship between electrically evoked compound action potential thresholds and behavioral T-levels in implanted children with cochlear nerve deficiency.
Chao, Xiuhua; Wang, Ruijie; Luo, Jianfen; Wang, Haibo; Fan, Zhaomin; Xu, Lei.
Afiliação
  • Chao X; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China.
  • Wang R; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China.
  • Luo J; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China.
  • Wang H; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China.
  • Fan Z; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China.
  • Xu L; Department of Otolaryngology-Head and Neck Surgery, Shandong Provincial ENT Hospital,, Shandong University, Jinan, 250022, People's Republic of China. sdphxl@126.com.
Sci Rep ; 13(1): 4309, 2023 03 15.
Article em En | MEDLINE | ID: mdl-36922582
ABSTRACT
It is challenging to program children with cochlear nerve deficiency (CND) due to limited auditory and speech abilities or concurrent neurological deficits. Electrically evoked compound action potential (ECAP) thresholds have been widely used by many audiologists to help cochlear implant programming for children who cannot cooperate with behavioral testing. However, the relationship between ECAP thresholds and behavioral levels of cochlear nerve in children with CND remains unclear. This study aimed to investigate how well ECAP thresholds are related to behavioral thresholds in the MAP for children with CND. This study included 29 children with CND who underwent cochlear implantation. For each participant, ECAP thresholds and behavioral T-levels were measured at three electrode locations across the electrode array post-activation. The relationship between ECAP thresholds and behavioral T-levels was analyzed using Pearson's correlation coefficient. The results showed that ECAP thresholds were significantly correlated with behavioral T-levels at the basal, middle, and apical electrodes. ECAP thresholds were equal to or higher than the behavioral T-levels for all tested electrodes, and fell within MAP's dynamic range for approximately 90% of the tested electrodes. Moreover, the contour of the ECAP thresholds was similar to the contour of T-levels across electrodes for most participants. ECAP thresholds can help audiologists select stimulation levels more efficiently for children with CND who cannot provide sufficient behavioral response.