Your browser doesn't support javascript.
loading
Polymerization shrinkage of light-cured conventional and bulk-fill composites -The effect of cavity depth and post-curing.
Akiya, Satoshi; Sato, Kento; Kibe, Kouta; Tichy, Antonin; Hiraishi, Noriko; Prasansuttiporn, Taweesak; Hosaka, Keiichi; Foxton, Richard M; Shimada, Yasushi; Nakajima, Masatoshi.
Afiliação
  • Akiya S; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.
  • Sato K; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.
  • Kibe K; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.
  • Tichy A; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.
  • Hiraishi N; Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague.
  • Prasansuttiporn T; Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.
  • Hosaka K; Department of Restorative Dentistry and Periodontology, Faculty of Dentistry, Chiang Mai University.
  • Foxton RM; Department of Regenerative Dental Medicine, Tokushima University.
  • Shimada Y; Institute of Global Affairs, Tokyo Medical and Dental University.
  • Nakajima M; Institute of Global Affairs, Tokyo Medical and Dental University.
Dent Mater J ; 42(3): 426-432, 2023 May 30.
Article em En | MEDLINE | ID: mdl-37032103
ABSTRACT
Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5 mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1 mm and 2 mm (p<0.05), and another drop was observed between 3 mm and 4 mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2 mm and 3 mm (p<0.05), but %VH exceeded 90% even in 5 mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3 mm.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Cárie Dentária Limite: Humans Idioma: En Revista: Dent Mater J Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Cárie Dentária Limite: Humans Idioma: En Revista: Dent Mater J Ano de publicação: 2023 Tipo de documento: Article