Your browser doesn't support javascript.
loading
Validation of immunoassays for the Chlamydia trachomatis antigen Pgp3 using a chimeric monoclonal antibody.
Goodhew, Brook; Tang, Xiaoling; Goldstein, Jason; Lee, Joo; Martin, Diana; Gwyn, Sarah.
Afiliação
  • Goodhew B; Division of Parasitic Diseases and Malaria, Centers for Disease Control and Prevention, Atlanta, Georgia.
  • Tang X; Division of Scientific Resources, Centers for Disease Control and Prevention, Atlanta, Georgia.
  • Goldstein J; Division of Scientific Resources, Centers for Disease Control and Prevention, Atlanta, Georgia.
  • Lee J; Division of Scientific Resources, Centers for Disease Control and Prevention, Atlanta, Georgia.
  • Martin D; Division of Parasitic Diseases and Malaria, Centers for Disease Control and Prevention, Atlanta, Georgia.
  • Gwyn S; Division of Parasitic Diseases and Malaria, Centers for Disease Control and Prevention, Atlanta, Georgia. yme8@cdc.gov.
Sci Rep ; 13(1): 7281, 2023 05 04.
Article em En | MEDLINE | ID: mdl-37142607
ABSTRACT
Seroepidemiology, or measuring antibodies to pathogens to estimate population-level exposure, can provide useful public health data. The tests used, however, often lack sufficient validation data due to absence of a gold standard. For many pathogens, serum antibodies can be detected long after resolution of infection, but infection status is often used as a gold standard for antibody positivity. To ensure that recently developed antibody tests for seroepidemiology of Chlamydia trachomatis (Ct), the causative agent of urogenital chlamydia and the blinding eye disease trachoma, have high performance, we generated a chimeric antibody to the immunodominant Ct antigen Pgp3. Two clones were selected to evaluate the test performance of three assays to measure antibodies to Pgp3 multiplex bead assay (MBA), enzyme-linked immunosorbent assay (ELISA), and lateral flow assay (LFA). Overall, each assay demonstrated high accuracy and precision when tested using either clone, and the clones were stable when stored at - 20 °C and 4 °C for almost 2 years. The limit of detection was similar for MBA and LFA, but almost a log-fold higher (i.e. less sensitive) using ELISA. Overall, the chimeric antibodies represent stable control reagents for tests with robust performance and will facilitate deployment of these tests to other laboratories.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por Chlamydia / Chlamydia trachomatis Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Geórgia País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por Chlamydia / Chlamydia trachomatis Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Geórgia País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM