Your browser doesn't support javascript.
loading
Cu-MOFs/GOx Bifunctional Probe-Based Synergistic Signal Amplification Strategy: Toward Highly Sensitive Closed Bipolar Electrochemiluminescence Immunoassay.
Chen, Chen; Wang, Yu-Ling; Lin, Xiao; Ma, Shu-Hui; Cao, Jun-Tao; Liu, Yan-Ming.
Afiliação
  • Chen C; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Wang YL; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Lin X; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Ma SH; Xinyang Central Hospital, Xinyang 464000, China.
  • Cao JT; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Liu YM; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
ACS Appl Mater Interfaces ; 15(19): 22959-22966, 2023 May 17.
Article em En | MEDLINE | ID: mdl-37147771
ABSTRACT
A closed bipolar electrochemiluminescence (BP-ECL) platform for sensitive prostate specific antigen (PSA) detection was proposed based on a novel synergistic signal amplification strategy. Specifically, glucose oxidase-loaded Cu-based metal-organic frameworks (Cu-MOFs/GOx) as bifunctional probes were bridged on the anodic interface with the target PSA as the intermediate unit. In virtue of the large loading capacity of Cu-MOFs, a large amount of a co-reactant, i.e., H2O2 in this L-012-based ECL system and gluconic acid were generated on the anodic pole in the presence of glucose. The generated gluconic acid could effectively degrade the Cu-MOFs to release Cu2+ which greatly accelerates the formation of highly active intermediates from co-reactant H2O2, boosting the ECL intensity. As for the cathodic pole, K3Fe(CN)6 with a lower reduction potential is used to reduce the driving voltage and speed up the reaction rate, further strengthening the ECL intensity. Thanks to the synergistic signal amplification effect at both two electrode poles of the BP-ECL system, highly sensitive detection of PSA was realized with a detection limit of 5.0 × 10-14 g/mL and a wide linear range of 1.0 × 10-13-1.0 × 10-7 g/mL. The strategy provides a novel way for signal amplification in the BP-ECL biosensing field.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Prostático Específico Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Prostático Específico Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China