Arthroscopic treatment of tibial intercondylar eminence fractures in skeletally immature patients with bioabsorbable nails.
Uboldi, Francesco M; Trezza, Paolo; Panuccio, Elena; Memeo, Antonio.
Afiliação
  • Uboldi FM; ASST Gaetano Pini - CTO, Pediatric Orthopedic Department, Milan. fraubo@gmail.com.
  • Trezza P; ASST Gaetano Pini - CTO, Pediatric Orthopedic Department, Milan. trezzap7@gmail.com.
  • Panuccio E; ASST Gaetano Pini - CTO, Pediatric Orthopedic Department, Milan. elenapanuccio@gmail.com.
  • Memeo A; ASST Gaetano Pini - CTO, Pediatric Orthopedic Department, Milan. Antonio.Memeo@asst-pini-cto.it.
Pediatr Med Chir ; 44(s1)2022 Oct 28.
Article em En | MEDLINE | ID: mdl-37184311
ABSTRACT
Fractures involving tibial eminence caused by ACL avulsion lesion most frequently occur paediatric patients. Satisfactory reduction in displaced fractures cannot be achieved through conservative treatment, while arthroscopy-assisted fixation technique represents the gold standard to reduce and to fix articular fractures and several effective implants have been used to treat this kind of fractures. In our retrospective study, we proposed a different arthroscopic technique to fix Type II and Type III tibial eminence fractures by using bioabsorbable nails. Nineteen patients, aged 6 to 13 years were treated with arthroscopic reduction and fixation of the fragment using bioabsorbable nails. At 6-month follow-up, all patients showed a decrease of less than 2mm of the anterior edge. All patients at maximum follow-up reached a full knee flexion/extension. IKDC subjective mean score at six-month was 88.14.2 points (range 80-95; p<0.01). For what concerns the Tegner Activity Scale, the mean value of 5.51 (range 3-7) prior to the surgery changed into 5.10.9 (range 3-6) at 6 months. No inflammatory reactions were reported and all fractures healed without complications. The objective IKDC grade A was reported in 18 patients and grade B in one patient, having a "nearly normal" range of motion item (92% compared to contralateral). Results can be compared to other surgical procedures described in the literature, having the same fast learning curve increase and limited complications, beside the fact that a second operation for metallic implants removal was avoided.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia Tipo de estudo: Observational_studies Limite: Child / Humans Idioma: En Revista: Pediatr Med Chir Ano de publicação: 2022 Tipo de documento: Article País de publicação: IT / ITALIA / ITALY / ITÁLIA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia Tipo de estudo: Observational_studies Limite: Child / Humans Idioma: En Revista: Pediatr Med Chir Ano de publicação: 2022 Tipo de documento: Article País de publicação: IT / ITALIA / ITALY / ITÁLIA