Your browser doesn't support javascript.
loading
Performance benchmarking microplate-immunoassays for quantifying target-specific cysteine oxidation reveals their potential for understanding redox-regulation and oxidative stress.
Tuncay, Ahmet; Crabtree, Daniel R; Muggeridge, David J; Husi, Holger; Cobley, James N.
Afiliação
  • Tuncay A; Division of Biomedical Science, Life Science Innovation Centre, University of the Highlands and Islands, Inverness, IV2 5NA, Scotland, UK.
  • Crabtree DR; Division of Biomedical Science, Life Science Innovation Centre, University of the Highlands and Islands, Inverness, IV2 5NA, Scotland, UK.
  • Muggeridge DJ; Edinburgh Napier University, Edinburgh, Scotland, UK.
  • Husi H; Division of Biomedical Science, Life Science Innovation Centre, University of the Highlands and Islands, Inverness, IV2 5NA, Scotland, UK.
  • Cobley JN; Division of Biomedical Science, Life Science Innovation Centre, University of the Highlands and Islands, Inverness, IV2 5NA, Scotland, UK; Cysteine Redox Technology Group, Life Science Innovation Centre, University of the Highlands and Islands, Inverness, IV2 5NA, Scotland, UK. Electronic address: j
Free Radic Biol Med ; 204: 252-265, 2023 08 01.
Article em En | MEDLINE | ID: mdl-37192685
ABSTRACT
The antibody-linked oxi-state assay (ALISA) for quantifying target-specific cysteine oxidation can benefit specialist and non-specialist users. Specialists can benefit from time-efficient analysis and high-throughput target and/or sample n-plex capacities. The simple and accessible "off-the-shelf" nature of ALISA brings the benefits of oxidative damage assays to non-specialists studying redox-regulation. Until performance benchmarking establishes confidence in the "unseen" microplate results, ALISA is unlikely to be widely adopted. Here, we implemented pre-set pass/fail criteria to benchmark ALISA by robustly evaluating immunoassay performance in diverse biological contexts. ELISA-mode ALISA assays were accurate, reliable, and sensitive. For example, the average inter-assay CV for detecting 20%- and 40%-oxidised PRDX2 or GAPDH standards was 4.6% (range 3.6-7.4%). ALISA displayed target-specificity. Immunodepleting the target decreased the signal by ∼75%. Single-antibody formatted ALISA failed to quantify the matrix-facing alpha subunit of the mitochondrial ATP synthase. However, RedoxiFluor quantified the alpha subunit displaying exceptional performance in the single-antibody format. ALISA discovered that (1) monocyte-to-macrophage differentiation amplified PRDX2-specific cysteine oxidation in THP-1 cells and (2) exercise increased GAPDH-specific cysteine oxidation in human erythrocytes. The "unseen" microplate data were "seen-to-be-believed" via orthogonal visually displayed immunoassays like the dimer method. Finally, we established target (n = 3) and sample (n = 100) n-plex capacities in ∼4 h with 50-70 min hands-on time. Our work showcases the potential of ALISA to advance our understanding of redox-regulation and oxidative stress.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benchmarking / Cisteína Limite: Humans Idioma: En Revista: Free Radic Biol Med Assunto da revista: BIOQUIMICA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benchmarking / Cisteína Limite: Humans Idioma: En Revista: Free Radic Biol Med Assunto da revista: BIOQUIMICA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido