Your browser doesn't support javascript.
loading
Validating Homogeneity for a Novel 3-Dimensional Tissue Phantom Modeling System of the Human Maxilla.
Sourvanos, Dennis; Hall Morales, Ryan D; Dimofte, Andreea; Fiorellini, Joseph P; Zhu, Timothy C.
Afiliação
  • Sourvanos D; Department of Periodontics, School of Dental Medicine, University of Pennsylvania, PA, USA.
  • Hall Morales RD; Center for Innovation and Precision Dentistry (CiPD), School of Dental Medicine, School of Engineering, University of Pennsylvania, PA, USA.
  • Dimofte A; Institute for Translational Medicine and Therapeutics (ITMAT), Perelman School of Medicine, University of Pennsylvania, PA, USA.
  • Fiorellini JP; Department of Radiation Oncology, Perelman Center for Advanced Medicine, University of Pennsylvania, PA, USA.
  • Zhu TC; Department of Radiation Oncology, Perelman Center for Advanced Medicine, University of Pennsylvania, PA, USA.
Article em En | MEDLINE | ID: mdl-37206702
ABSTRACT
Silicon phantom models have been utilized to calculate light fluence in patients being treated with Photodynamic Therapy (PDT). This application can be utilized for other non-ionizing wavelength therapies such as Photobiomodulation (PBM). We have developed a novel protocol to validate homogeneity for 3-dimensional silicon phantom models of the human maxilla. Accurately quantifying the light profiles of human tissue can accommodate for varying optical properties that occur between subjects. More importantly, this can help optimize light fluence dosimetry calculations to achieve intended results. Silicon models of identical composition were fabricated into two different shapes 1 flat-planar cylindrical shaped model, 2) non-flat planar (3-dimensional) mold of the human maxilla. Fabricating homogenous silicon phantom models continues to be a challenge as micro-bubbles can contaminate the compound during the curing process. Integrating both proprietary CBCT and handheld surface acquisition imaging devices confirmed our results to be within 0.5mm of accuracy. This protocol was specifically used to cross-reference and validate homogeneity at various depths of penetration. These results present the first known successful validation of identical silicon tissue phantoms with a flat-planar surface vs. a non-flat 3D planar surface. This proof-of-concept phantom validation protocol is sensitive to the specific variations of 3-dimensional surfaces and can be applied to a workflow used to capture accurate light fluence calculations in the clinical setting.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Proc SPIE Int Soc Opt Eng Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Proc SPIE Int Soc Opt Eng Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos