Your browser doesn't support javascript.
loading
Development and Validation of Stability Indicating RP-HPLC Method for the Estimation of Glycopyrrolate and Neostigmine in Bulk and Injection.
Agarwal, Babita; Jagdale, Sachin; Kadam, Prasad; Sakpal, Pramod; Nalawade, Santaji; Maske, Shivraj; Dale, Pooja.
Afiliação
  • Agarwal B; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
  • Jagdale S; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
  • Kadam P; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
  • Sakpal P; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
  • Nalawade S; Callidus Research Laboratories Pvt. Ltd, PAP-A-29/1, Chakan Industrial Area, Phase-IV, Nighoje, Pune, Tal-Khed, Maharashtra 410501, India.
  • Maske S; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
  • Dale P; Pharmaceutical Quality Assurance, Marathwada Mitra Mandal's College of Pharmacy, Thergaon, Pune, Maharashtra 411033, India.
J Chromatogr Sci ; 62(3): 213-221, 2024 Mar 23.
Article em En | MEDLINE | ID: mdl-37207317
ABSTRACT
A stability indicating RP-HPLC method is suggested for determination of Glycopyrrolate-Neostigmine (GLY/NEO) in bulk drugs and injection formulation. GLY/NEO were eluted from a Chromolith High Resolution RP-18e (100 mm×4.6 mm) with buffer solution (pH 3.0) as mobile phase A and a mixture of HPLC grade acetonitrile and water mixture (9010) as mobile phase B. The gradient was optimized with a flowrate of 0.5 mL/min and wavelength of 222 nm. A complete analytical method validation was effectively carried out as per ICH Q2 (R1) guidelines. Recovery studies were performed at 50-150% level of working concentrations, and results were in the range of 99-101%. The linearity was detected in the range of LOQ to 200% of the specification limits i.e., 0.5% each for NEO and GLY, 0.01% for NEO Impurity B and 1.0% for rest of the impurities with respect to the test concentration of the respective components. For stability study, various stress conditions such as acid, base, oxidation and thermal as per ICH guidelines were studied. The high recovery and low relative standard deviation confirm the suitability of proposed method that can be employed for the routine analysis in bulk and pharmaceutical formulation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicopirrolato / Neostigmina Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicopirrolato / Neostigmina Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia