Your browser doesn't support javascript.
loading
Fast Response Facile Fabricated IDE-Based Ultra-sensitive Humidity Sensor for Medical Applications.
Ullah, Asad; Zulfiqar, Muhammad Hamza; Khan, Muhammad Atif; Zubair, Muhammad; Mehmood, Muhammad Qasim; Massoud, Yehia.
Afiliação
  • Ullah A; MicroNano Lab, Department of Electrical Engineering, Information Technology University (ITU) of the Punjab, Ferozepur Road, Lahore 54600, Pakistan.
  • Zulfiqar MH; Department of Biomedical Engineering, University of Engineering and Technology (UET), Narowal Campus, Lahore 54890, Pakistan.
  • Khan MA; Innovative Technologies Laboratories (ITL), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955 Saudi Arabia.
  • Zubair M; Innovative Technologies Laboratories (ITL), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955 Saudi Arabia.
  • Mehmood MQ; MicroNano Lab, Department of Electrical Engineering, Information Technology University (ITU) of the Punjab, Ferozepur Road, Lahore 54600, Pakistan.
  • Massoud Y; Innovative Technologies Laboratories (ITL), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955 Saudi Arabia.
ACS Omega ; 8(19): 16842-16850, 2023 May 16.
Article em En | MEDLINE | ID: mdl-37214719
ABSTRACT
An eco-friendly, biodegradable, flexible, and facile fabricated interdigital electrode-based capacitive humidity sensor with applications in health and medicine has been reported here. Several sensors use copper tape as electrodes on the polyethylene terephthalate (PET) substrate, with non-woven paper as the sensing layer. Two different configurations of sensors were tested, i.e., with and without pores in the PET substrate. The sensing performance of both sensors has been tested for relative humidity ranging from 35 to 100% at temperatures ranging from 20 to 50 °C. The capacitance of the sensor varies linearly in response to the change in humidity. The sensor with pores shows a response from 28 to 630 pF as the humidity varied from 35 to 100%, whereas the sensor without pores responded from 22 to 430 pF. The response and recovery times of the fabricated sensor are observed as ∼2.4, and ∼1.8 s, respectively, and the sensitivity is 9.67 pF/% RH. The sensors are tested multiple times, and repeatable results are achieved each time with an accuracy of ±0.22%. Further, the sensor's response is also stable for different ranges of temperatures. Finally, to demonstrate an application of the proposed sensor, it has been utilized to monitor respiration through nose and mouth breathing. The low-cost, stable, repeatable, and highly sensitive response makes our fabricated sensor a promising candidate for practical field applications.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: ACS Omega Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Paquistão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: ACS Omega Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Paquistão