Your browser doesn't support javascript.
loading
A comparative analysis of APGAR score and the gold standard in the diagnosis of birth asphyxia at a tertiary health facility in Kenya.
Njie, Albertine Enjema; Nyandiko, Winstone Mokaya; Ahoya, Phinehas Ademi; Moutchia, Jude Suh.
Afiliação
  • Njie AE; Department of Child Health and Pediatrics, College of Health Sciences-Moi University, Eldoret, Kenya.
  • Nyandiko WM; Department of Child Health and Pediatrics, College of Health Sciences-Moi University, Eldoret, Kenya.
  • Ahoya PA; Academic Model Providing Access to Healthcare, Eldoret, Kenya.
  • Moutchia JS; Directorate of Child Health and Pediatrics, Moi Teaching and Referral Hospital, Eldoret, Kenya.
PLoS One ; 18(5): e0285828, 2023.
Article em En | MEDLINE | ID: mdl-37224111
BACKGROUND: Birth asphyxia is a consistent key contributor to neonatal morbidity and mortality, notably in sub-Saharan Africa. The APGAR score, though a globally used diagnostic tool for birth asphyxia, remains largely understudied especially in resource-poor settings. OBJECTIVE: This study determined how effectively the APGAR score is used to diagnose birth asphyxia in comparison to the gold standard (umbilical cord blood pH <7 with neurologic involvement) at Moi Teaching and Referral Hospital (MTRH), and identified healthcare provider factors that affect ineffective use of the score. METHODS: Using a quantitative cross-sectional hospital-based design, term babies born in MTRH who weighed ≥2500g were randomly and systematically sampled; and healthcare providers who assign APGAR scores were enrolled via a census. Umbilical cord blood was drawn at birth and at 5minutes for pH analysis. APGAR scores assigned by healthcare providers were recorded. Effective use of the APGAR score was determined by sensitivity, specificity, positive and negative predictive values. At a significance level of 0.05, multiple logistic regression analysis identified the independent provider-associated factors affecting ineffective use of the APGAR score. RESULTS: We enrolled 102 babies, and 50 (49%) were females. Among the 64 healthcare providers recruited, 40 (63%) were female and the median age was 34.5years [IQR: 31.0, 37.0]. Assigned APGAR scores had a sensitivity of 71% and specificity of 89%, with positive and negative predictive values of 62% and 92% respectively. Healthcare provider factors associated with ineffective APGAR score use included: instrumental delivery (OR: 8.83 [95% CI: 0.79, 199]), lack of access to APGAR scoring charts (OR: 56.0 [95% CI: 12.9, 322.3]), and neonatal resuscitation (OR: 23.83 [95% CI: 6.72, 101.99]). CONCLUSION: Assigned APGAR scores had low sensitivity and positive predictive values. Healthcare provider factors independently associated with ineffective APGAR scoring include; instrumental delivery, lack of access to APGAR scoring charts, and neonatal resuscitation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asfixia / Asfixia Neonatal Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Aspecto: Patient_preference Limite: Adult / Female / Humans / Infant / Male / Newborn / Pregnancy País/Região como assunto: Africa Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Quênia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asfixia / Asfixia Neonatal Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Aspecto: Patient_preference Limite: Adult / Female / Humans / Infant / Male / Newborn / Pregnancy País/Região como assunto: Africa Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Quênia País de publicação: Estados Unidos