Your browser doesn't support javascript.
loading
Regularization-Based 2D Strain Tensor Imaging in Quasi-Static Ultrasound Elastography SAGE Publications.
Duroy, Anne-Lise; Detti, Valérie; Coulon, Agnès; Basset, Olivier; Brusseau, Elisabeth.
Afiliação
  • Duroy AL; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM Saint-Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Villeurbanne, France.
  • Detti V; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM Saint-Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Villeurbanne, France.
  • Coulon A; Département de radiologie, Centre de lutte contre le cancer Léon Bérard, Lyon, France.
  • Basset O; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM Saint-Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Villeurbanne, France.
  • Brusseau E; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM Saint-Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Villeurbanne, France.
Ultrason Imaging ; 45(4): 187-205, 2023 07.
Article em En | MEDLINE | ID: mdl-37231671
Accurately estimating all strain components in quasi-static ultrasound elastography is crucial for the full analysis of biological media. In this study, 2D strain tensor imaging was investigated, focusing on the use of a regularization method to improve strain images. This method enforces the tissue property of (quasi-) incompressibility, while penalizing strong field variations, to smooth the displacement fields and reduce the noise in the strain components. The performance of the method was assessed with numerical simulations, phantoms, and in vivo breast tissues. For all the media examined, the results showed a significant improvement in both lateral displacement and strain, while axial fields were only slightly modified by the regularization. The introduction of penalty terms allowed us to obtain shear strain and rotation elastograms where the patterns around the inclusions/lesions were clearly visible. In phantom cases, the findings were consistent with the results obtained from the modeling of the experiments. Finally, the easier detectability of the inclusions/lesions in the final lateral strain images was associated with higher elastographic contrast-to-noise ratios (CNRs), with values in the range of [0.54-9.57] versus [0.08-0.38] before regularization.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Ultrason Imaging Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Ultrason Imaging Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido