The Influence of a Novel, Crenelated Design of CAD-CAM Ceramic Veneers on the Debonding Strength.
Maroiu, Alexandra-Cristina; Jivanescu, Anca; Șerban, Dan-Andrei; Negru, Radu-Marcel; Duma, Virgil-Florin; Sinescu, Cosmin; Romînu, Mihai.
Afiliação
  • Maroiu AC; Research Center in Dental Medicine Using Conventional and Alternative Technologies, School of Dental Medicine, "Victor Babes" University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania.
  • Jivanescu A; Department of Prosthodontics, "Victor Babes" University of Medicine and Pharmacy, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania.
  • Șerban DA; Department of Prosthodontics, "Victor Babes" University of Medicine and Pharmacy, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania.
  • Negru RM; TADERP Research Center, 300041 Timisoara, Romania.
  • Duma VF; Faculty of Mechanics, Polytechnic University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timisoara, Romania.
  • Sinescu C; Faculty of Mechanics, Polytechnic University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timisoara, Romania.
  • Romînu M; 3OM Optomechatronics Group, Faculty of Engineering, "Aurel Vlaicu" University of Arad, Str. Elena Dragoi No. 2, 310177 Arad, Romania.
Materials (Basel) ; 16(10)2023 May 12.
Article em En | MEDLINE | ID: mdl-37241322
ABSTRACT
(1)

Background:

Aesthetic dentistry has become one of the most dynamic fields in modern dental medicine. Ceramic veneers represent the most appropriate prosthetic restorations for smile enhancement, due to their minimal invasiveness and highly natural appearance. For long-term clinical success, accurate design of both tooth preparation and ceramic veneers is of paramount importance. The aims of this in vitro study were to assess the stress in anterior teeth restored with Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) ceramic veneers and compare the resistance to detachment and the fracture of ceramic veneers prepared using two different designs. (2)

Methods:

Sixteen lithium disilicate ceramic veneers were designed and milled using the CAD-CAM technology and divided into two groups according to the preparations (n = 8) Group 1, conventional (CO), with linear marginal contour and Group 2, crenelated (CR), the latter with our novel (patented) sinusoidal marginal design. All samples were bonded to anterior natural teeth. The mechanical resistance to detachment and fracture was investigated by applying bending forces on the incisal margin of the veneers in order to determine which type of preparation leads to better adhesion. An analytic method was employed, as well, and the results of the two approaches were compared. (3)

Results:

The mean values of the maximum force recorded at the veneer detachment were 78.82 ± 16.55 N for the CO group and 90.20 ± 29.81 N for the CR group. The relative increase, equal to 14.43%, demonstrated that the novel CR tooth preparation provided higher adhesive joints. In order to determine the stress distribution within the adhesive layer, a finite element analysis (FEA) was performed. The statistical t-test showed that the mean value of the maximum normal stresses is higher for the CR-type preparations. (4)

Conclusions:

The patented CR veneers represent a practical solution to augment the adhesion and mechanical properties of ceramic veneers. The obtained results demonstrated that CR adhesive joints triggered higher mechanical and adhesive forces, which subsequently led to a higher resistance to detachment and fracture.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Romênia