Your browser doesn't support javascript.
loading
False-Positive Screening and Confirmatory HIV Diagnostic Test in a Patient with Cured SARS-CoV-2 Infection Is Not Mediated by Env/Spike Cross-Reactive Antibodies.
Elsner, Carina; Appeltrath, Gwenllian A; Konik, Margarethe; Parreuter, Janine; Broecker-Preuss, Martina; Krawczyk, Adalbert; Esser, Stefan; Sammet, Stefanie; Karsten, Christina B.
Afiliação
  • Elsner C; Institute for Virology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Appeltrath GA; Institute for Translational HIV Research, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Konik M; Department of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany.
  • Parreuter J; Institute for Translational HIV Research, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Broecker-Preuss M; Laboratory Medicine Section, Department of Medicine, University Hospital Knappschaftskrankenhaus Bochum, Ruhr University Bochum, 44892 Bochum, Germany.
  • Krawczyk A; Institute for Virology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Esser S; Department of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University Duisburg-Essen, 45147 Essen, Germany.
  • Sammet S; Institute for Translational HIV Research, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Karsten CB; Clinic of Dermatology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
Viruses ; 15(5)2023 05 13.
Article em En | MEDLINE | ID: mdl-37243248
ABSTRACT
Acute SARS-CoV-2 infection has been associated with false-positive HIV screening tests. The underlying mechanism is unclear, and for clinical cases, evidence beyond a temporal connection is missing. However, several experimental studies point toward SARS-CoV-2 spike/HIV-1 envelope (Env) cross-reactive antibodies (Abs) as a cause. Here, we present the first case of an individual with convalescent SARS-CoV-2 infection testing false positive in both an HIV screening and confirmatory test. Longitudinal sampling showed that the phenomenon was temporary but lasted for at least 3 months before waning. After excluding a multitude of common determinants for assay interference, we further show by antibody depletion studies that SARS-CoV-2-spike-specific Abs did not cross-react with HIV-1 gp120 in the patient sample. No additional case of HIV test interference was identified in a cohort of 66 individuals who presented to a post-COVID-19 outpatient clinic. We conclude the SARS-CoV-2-associated HIV test interference to be a temporary process capable of disturbing both screening and confirmatory assays. The assay interference is short-lived and/or rare but should be considered by physicians as a possible explanation for unexpected HIV diagnostic results in patients with a recent SARS-CoV-2 infection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Viruses Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / COVID-19 Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Viruses Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha