Your browser doesn't support javascript.
loading
The Impact of Commercially Available Dry Mouth Products on the Corrosion Resistance of Common Dental Alloys.
Turkina, Anna Yu; Makeeva, Irina M; Dubinin, Oleg N; Bondareva, Julia V; Chernodoubov, Daniil A; Shibalova, Anastasia A; Arzukanyan, Alina V; Antoshin, Artem A; Timashev, Peter S; Evlashin, Stanislav A.
Afiliação
  • Turkina AY; Therapeutic Dentistry Department, Institute for Dentistry, I.M. Sechenov First Moscow State Medical University, 8-2 Trubetskaya Str., 119991 Moscow, Russia.
  • Makeeva IM; Therapeutic Dentistry Department, Institute for Dentistry, I.M. Sechenov First Moscow State Medical University, 8-2 Trubetskaya Str., 119991 Moscow, Russia.
  • Dubinin ON; Center for Materials Technologies, Skolkovo Institute of Science and Technology, 30, Bld. 1 Bolshoy Boulevard, 121205 Moscow, Russia.
  • Bondareva JV; World-Class Research Center, Saint Petersburg State Marine Technical University, Lotsmanskaya Str. 3, 190121 Saint Petersburg, Russia.
  • Chernodoubov DA; Center for Materials Technologies, Skolkovo Institute of Science and Technology, 30, Bld. 1 Bolshoy Boulevard, 121205 Moscow, Russia.
  • Shibalova AA; National Research Center "Kurchatov Institute", 123182 Moscow, Russia.
  • Arzukanyan AV; Institute of Nanotechnology of Microelectronics of the Russian Academy of Sciences, Leninsky Prospect, 32A, 119991 Moscow, Russia.
  • Antoshin AA; Therapeutic Dentistry Department, Institute for Dentistry, I.M. Sechenov First Moscow State Medical University, 8-2 Trubetskaya Str., 119991 Moscow, Russia.
  • Timashev PS; Institute for Regenerative Medicine, I.M. Sechenov First Moscow State Medical University, 8-2 Trubetskaya Str., 119991 Moscow, Russia.
  • Evlashin SA; World-Class Research Center "Digital Biodesign and Personalized Healthcare", I.M. Sechenov First Moscow State Medical University, 8-2 Trubetskaya Str., 119991 Moscow, Russia.
Materials (Basel) ; 16(11)2023 Jun 05.
Article em En | MEDLINE | ID: mdl-37297329
ABSTRACT
Dental implants are thought to be implanted for life, but throughout their lifespan, they function in aggressive oral environment, resulting in corrosion of the material itself as well as possible inflammation of adjacent tissues. Therefore, materials and oral products for people with metallic intraoral appliances must be chosen carefully. The purpose of this study was to investigate the corrosion behavior of common titanium and cobalt-chromium alloys in interaction with various dry mouth products using electrochemical impedance spectroscopy (EIS). The study showed that different dry mouth products lead to different open circuit potentials, corrosion voltages, and currents. The corrosion potentials of Ti64 and CoCr ranged from -0.3 to 0 V and -0.67 to 0.7 V, respectively. In contrast to titanium, pitting corrosion was observed for the cobalt-chromium alloy, leading to the release of Co and Cr ions. Based on the results, it can be argued that the commercially available dry mouth remedies are more favorable for dental alloys in terms of corrosion compared to Fusayama Meyer's artificial saliva. Thus, to prevent undesirable interactions, the individual characteristics of not only the composition of each patient's tooth and jaw structure, but also the materials already used in their oral cavity and oral hygiene products, must be taken into account.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Federação Russa