Your browser doesn't support javascript.
loading
Validation of collaborative cyberspace virtual reality oculometry enhanced with near real-time spatial audio.
Maloca, Peter M; Zarranz-Ventura, Javier; Valmaggia, Philippe; Faludi, Balázs; Zelechowski, Marek; Tufail, Adnan; Zentai, Norbert Z; Scholl, Hendrik P N; Cattin, Philippe C.
Afiliação
  • Maloca PM; Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland. peter.maloca@iob.ch.
  • Zarranz-Ventura J; Department of Ophthalmology, University Hospital Basel, 4031, Basel, Switzerland. peter.maloca@iob.ch.
  • Valmaggia P; Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK. peter.maloca@iob.ch.
  • Faludi B; Hospital Clínic of Barcelona, University of Barcelona, 08036, Barcelona, Spain.
  • Zelechowski M; Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland.
  • Tufail A; Department of Ophthalmology, University Hospital Basel, 4031, Basel, Switzerland.
  • Zentai NZ; Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK.
  • Scholl HPN; Centre for Medical Image Analysis & Navigation, University of Basel, 4123, Allschwil-Basel, Switzerland.
  • Cattin PC; Centre for Medical Image Analysis & Navigation, University of Basel, 4123, Allschwil-Basel, Switzerland.
Sci Rep ; 13(1): 10076, 2023 06 21.
Article em En | MEDLINE | ID: mdl-37344554
ABSTRACT
Currently, most medical image data, such as optical coherence tomography (OCT) images, are displayed in two dimensions on a computer screen. Advances in computer information technology have contributed to the growing storage of these data in electronic form. However, the data are usually processed only locally on site. To overcome such hurdles, a cyberspace virtual reality (csVR) application was validated, in which interactive OCT data were presented simultaneously to geographically distant sites (Lucerne, London, and Barcelona) where three graders independently measured the ocular csVR OCT diameters. A total of 109 objects were measured, each three times, resulting in a total of 327 csVR measurements. A minor mean absolute difference of 5.3 µm was found among the 3 measurements of an object (standard deviation 4.2 µm, coefficient of variation 0.3% with respect to the mean object size). Despite the 5 h of online work, csVR was well tolerated and safe. Digital high-resolution OCT data can be remotely and collaboratively processed in csVR. With csVR, measurements and actions enhanced with spatial audio communication can be made consistently in near real time, even if the users are situated geographically far apart. The proposed visuo-auditory framework has the potential to further boost the convenience of digital medicine toward csVR precision and collaborative medicine.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica / Olho País/Região como assunto: Europa Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica / Olho País/Região como assunto: Europa Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça