Your browser doesn't support javascript.
loading
Performances of novel custom 3D-printed cutting guide in canine caudal maxillectomy: a cadaveric study.
Chambers, Aidan; Traverson, Marine; Neal, Shelby; Konala, Satyanarayana; Harrysson, Ola.
Afiliação
  • Chambers A; Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, United States.
  • Traverson M; Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, United States.
  • Neal S; Center for Additive Manufacturing and Logistics, College of Engineering, North Carolina State University, Raleigh, NC, United States.
  • Konala S; Center for Additive Manufacturing and Logistics, College of Engineering, North Carolina State University, Raleigh, NC, United States.
  • Harrysson O; Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, United States.
Front Vet Sci ; 10: 1127025, 2023.
Article em En | MEDLINE | ID: mdl-37360408
Introduction: Caudal maxillectomies are challenging procedures for most veterinary surgeons. Custom guides may allow the procedure to become more accessible. Methods: A cadaveric study was performed to evaluate the accuracy and efficiency of stereolithography guided (3D-printed) caudal maxillectomy. Mean absolute linear deviation from planned to performed cuts and mean procedure duration were compared pairwise between three study groups, with 10 canine cadaver head sides per group: 3D-printed guided caudal maxillectomy performed by an experienced surgeon (ESG) and a novice surgery resident (NSG), and freehand procedure performed by an experienced surgeon (ESF). Results: Accuracy was systematically higher for ESG versus ESF, and statistically significant for 4 of 5 osteotomies (p < 0.05). There was no statistical difference in accuracy between ESG and NSG. The highest absolute mean linear deviation for ESG was <2 mm and >5 mm for ESF. Procedure duration was statistically significantly longer for ESG than ESF (p < 0.001), and for NSG than ESG (p < 0.001). Discussion: Surgical accuracy of canine caudal maxillectomy was improved with the use of our novel custom cutting guide, despite a longer duration procedure. Improved accuracy obtained with the use of the custom cutting guide could prove beneficial in achieving complete oncologic margins. The time increase might be acceptable if hemorrhage can be adequately controlled in vivo. Further development in custom guides may improve the overall efficacy of the procedure.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Front Vet Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Front Vet Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Suíça