Your browser doesn't support javascript.
loading
SiC Electrochemical Sensor Validation for Alzheimer Aß42 Antigen Detection.
Montero-Arevalo, Brayan; Seufert, Bianca I; Hossain, Mohammad S; Bernardin, Evans; Takshi, Arash; Saddow, Stephen E; Schettini, Norelli.
Afiliação
  • Montero-Arevalo B; Department of Electrical and Electronic Engineering, Universidad del Norte, Barranquilla 081007, Colombia.
  • Seufert BI; Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
  • Hossain MS; Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
  • Bernardin E; Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
  • Takshi A; Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
  • Saddow SE; Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA.
  • Schettini N; Department of Electrical and Electronic Engineering, Universidad del Norte, Barranquilla 081007, Colombia.
Micromachines (Basel) ; 14(6)2023 Jun 16.
Article em En | MEDLINE | ID: mdl-37374847
Alzheimer's disease (AD) is a neurodegenerative disease with only late-stage detection; thus, diagnosis is made when it is no longer possible to treat the disease, only its symptoms. Consequently, this often leads to caregivers who are the patient's relatives, which adversely impacts the workforce along with severely diminishing the quality of life for all involved. It is, therefore, highly desirable to develop a fast, effective and reliable sensor to enable early-stage detection in an attempt to reverse disease progression. This research validates the detection of amyloid-beta 42 (Aß42) using a Silicon Carbide (SiC) electrode, a fact that is unprecedented in the literature. Aß42 is considered a reliable biomarker for AD detection, as reported in previous studies. To validate the detection with a SiC-based electrochemical sensor, a gold (Au) electrode-based electrochemical sensor was used as a control. The same cleaning, functionalization and Aß1-28 antibody immobilization steps were used on both electrodes. Sensor validation was carried out by means of Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) aiming to detect an 0.5 µg·mL-1 Aß42 concentration in 0.1 M buffer solution as a proof of concept. A repeatable peak directly related to the presence of Aß42 was observed, indicating that a fast SiC-based electrochemical sensor was constructed and may prove to be a useful approach for the early detection of AD.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Aspecto: Patient_preference Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Aspecto: Patient_preference Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Suíça