Your browser doesn't support javascript.
loading
Accuracy of serological tests in diagnosing mucosal leishmaniasis.
Oliveira, Diana; Lopes, Karine Ferreira; de Avelar, Daniel Moreira; Cota, Gláucia; Oliveira, Edward.
Afiliação
  • Oliveira D; Clinical Research and Public Politics in Infectious and Parasitic Diseases, Instituto René Rachou, Oswaldo Cruz Foundation, Belo Horizonte, Minas Gerais, Brazil.
  • Lopes KF; Clinical Research and Public Politics in Infectious and Parasitic Diseases, Instituto René Rachou, Oswaldo Cruz Foundation, Belo Horizonte, Minas Gerais, Brazil.
  • de Avelar DM; Clinical Research and Public Politics in Infectious and Parasitic Diseases, Instituto René Rachou, Oswaldo Cruz Foundation, Belo Horizonte, Minas Gerais, Brazil.
  • Cota G; Clinical Research and Public Politics in Infectious and Parasitic Diseases, Instituto René Rachou, Oswaldo Cruz Foundation, Belo Horizonte, Minas Gerais, Brazil. glaucia.cota@fiocruz.br.
  • Oliveira E; Clinical Research and Public Politics in Infectious and Parasitic Diseases, Instituto René Rachou, Oswaldo Cruz Foundation, Belo Horizonte, Minas Gerais, Brazil. edward.oliveira@fiocruz.br.
Parasitol Res ; 122(9): 2001-2010, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37391643
ABSTRACT
In this serum panel-based study, we evaluated the accuracy of serological tests originally developed for visceral leishmaniasis (VL), for diagnosis of mucosal leishmaniasis (ML). A total of five tests were evaluated, four of which are registered at the National Agency of Sanitary Surveillance (Agência Nacional de Vigilância Sanitária-ANVISA) (RIDASCREEN® Leishmania Ab from R-Biopharm AG., Leishmania ELISA IgG + IgM from Vircell S.L., IFI Leishmaniose Humana-BioManguinhos, and IT-LEISH® from Bio-Rad Laboratories, Inc.), and the other a direct agglutination test (DAT-LPC) prototype kit developed at Fiocruz. The panel was composed of 40 serum samples from patients with confirmed ML and 20 from patients with mucosal involvement and negative parasitological/molecular tests for leishmaniasis and confirmation of another etiology. All cases were treated from 2009 to 2016 in a referral center for leishmaniasis in Belo Horizonte, Minas Gerais, Brazil (Instituto René Rachou, Fiocruz). Diagnostic accuracy, based on the cut-off point for VL diagnosis, was 86.2% with RIDASCREEN® Leishmania Ab, 73.3% with Leishmania ELISA IgG + IgM, and 66.7% with IFI Leishmaniose Humana, while IT-LEISH® and DAT-LPC had the lowest accuracy (38.3%), despite high specificity (100% and 95%, respectively). New cut-off points defined with sera from ML patients improved accuracy from 86.2 to 89% (p = 0.64) and 73.3 to 88% (p = 0.04) for RIDASCREEN® Leishmania Ab and Leishmania ELISA IgG + IgM, respectively. Moreover, these tests presented greater sensitivity and immunoreactivity in patients with moderate/severe clinical ML forms. The data of this study suggest that ELISA assays can contribute to laboratory diagnosis, especially for patients with moderate or severe mucosal involvement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leishmania / Leishmaniose Visceral Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Parasitol Res Assunto da revista: PARASITOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leishmania / Leishmaniose Visceral Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Parasitol Res Assunto da revista: PARASITOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil