Your browser doesn't support javascript.
loading
Design and Evaluation of the Extended FBS Model Based Gaze-Control Power Wheelchair for Individuals Facing Manual Control Challenges.
Zhang, Xiaochen; Li, Jiazhen; Jin, Lingling; Zhao, Jie; Huang, Qianbo; Song, Ziyang; Liu, Xinyu; Luh, Ding-Bang.
Afiliação
  • Zhang X; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Li J; Guangdong International Center of Advanced Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Jin L; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Zhao J; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Huang Q; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Song Z; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Liu X; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
  • Luh DB; Department of Industrial Design, Guangdong University of Technology, Guangzhou 510090, China.
Sensors (Basel) ; 23(12)2023 Jun 14.
Article em En | MEDLINE | ID: mdl-37420738
ABSTRACT
This study addresses the challenges faced by individuals with upper limb disadvantages in operating power wheelchair joysticks by utilizing the extended Function-Behavior-Structure (FBS) model to identify design requirements for an alternative wheelchair control system. A gaze-controlled wheelchair system is proposed based on design requirements from the extended FBS model and prioritized using the MosCow method. This innovative system relies on the user's natural gaze and comprises three levels perception, decision making, and execution. The perception layer senses and acquires information from the environment, including user eye movements and driving context. The decision-making layer processes this information to determine the user's intended direction, while the execution layer controls the wheelchair's movement accordingly. The system's effectiveness was validated through indoor field testing, with an average driving drift of less than 20 cm for participates. Additionally, the user experience scale revealed overall positive user experiences and perceptions of the system's usability, ease of use, and satisfaction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cadeiras de Rodas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cadeiras de Rodas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China