Ultrasonic Interferometric Procedure for Quantifying the Bone-Implant Interface.
Lützelberger, Jan; Arneth, Philipp; Franck, Alexander; Drese, Klaus Stefan.
Afiliação
  • Lützelberger J; Institute of Sensor and Actuator Technology (ISAT), Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany.
  • Arneth P; Institute of Sensor and Actuator Technology (ISAT), Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany.
  • Franck A; Department of Trauma Surgery and Orthopedics, REGIOMED Clinical Center Coburg, Ketschendorfer Str. 33, 96450 Coburg, Germany.
  • Drese KS; School of Medicine, University of Split, 21000 Split, Croatia.
Sensors (Basel) ; 23(13)2023 Jun 26.
Article em En | MEDLINE | ID: mdl-37447790
ABSTRACT
The loosening of an artificial joint is a frequent and critical complication in orthopedics and trauma surgery. Due to a lack of accuracy, conventional diagnostic methods such as projection radiography cannot reliably diagnose loosening in its early stages or detect whether it is associated with the formation of a biofilm at the bone-implant interface. In this work, we present a non-invasive ultrasound-based interferometric measurement procedure for quantifying the thickness of the layer between bone and prosthesis as a correlate to loosening. In principle, it also allows for the material characterization of the interface. A well-known analytical model for the superposition of sound waves reflected in a three-layer system was combined with a new method in data processing to be suitable for medical application at the bone-implant interface. By non-linear fitting of the theoretical prediction of the model to the actual shape of the reflected sound waves in the frequency domain, the thickness of the interlayer can be determined and predictions about its physical properties are possible. With respect to determining the layer's thickness, the presented approach was successfully applied to idealized test systems and a bone-implant system in the range of approx. 200 µm to 2 mm. After further optimization and adaptation, as well as further experimental tests, the procedure offers great potential to significantly improve the diagnosis of prosthesis loosening at an early stage and may also be applicable to detecting the formation of a biofilm.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membros Artificiais / Interface Osso-Implante Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membros Artificiais / Interface Osso-Implante Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha